49
PremierLink™ Controller (Factory Option)
Fig. 71 — PremierLink Controller
The PremierLink controller (see Fig. 71) is compatible with
Carrier Comfort Network
®
(CCN) devices. This control is de-
signed to allow users the access and ability to change factory-
defined settings, thus expanding the function of the standard
unit control board. CCN service access tools include System
Pilot™, Touch Pilot™ and Service Tool. (Standard tier display
tools Navigator and Scrolling Marquee are not suitable for use
with latest PremierLink controller (Version 2.x).
The PremierLink controller is factory-mounted in the 50TC
unit’s main control box to the left of the Central Terminal
Board (CTB). Factory wiring is completed through harnesses
connected to the CTB thermostat. Field connections are made
at a 16-pole terminal block (TB3) located on the bottom shelf
of the unit control box in front of the PremierLink controller.
The factory-installed PremierLink controller includes the sup-
ply-air temperature (SAT) sensor. The outdoor air temperature
(OAT) sensor is included in the FIOP/accessory EconoMi$er 2
package.
The PremierLink controller requires the use of a Carrier
electronic thermostat or a CCN connection for time broadcast
to initiate its internal timeclock. This is necessary for broadcast
of time of day functions (occupied/unoccupied).
NOTE: PremierLink controller is shipped in Sensor mode.
To be used with a thermostat, the PremierLink controller
must be configured to Thermostat mode. Refer to Premier-
Link Configuration instructions for Operating Mode.
Fig. 72 — 50TC 08-14 Control Box Component PremierLink Locations
Содержание Carrier WeatherMaker 50TC A08 Series
Страница 4: ...4 Fig 2 Unit Dimensional Drawing Size 08 09 12 Units...
Страница 5: ...5 Fig 2 Unit Dimensional Drawing Size 08 09 12 Units cont...
Страница 6: ...6 Fig 3 Unit Dimensional Drawing Size 14 Unit...
Страница 7: ...7 Fig 3 Unit Dimensional Drawing Size 14 Unit cont...
Страница 9: ...9 Fig 4 Unit Dimensional Drawing Size 16 Unit cont...
Страница 13: ...13 Fig 8 Roof Curb Details Size 16 Unit...
Страница 33: ...33 Fig 62 Typical Humidi MiZer Adaptive Dehumidification System Humidistat Wiring 50TC 08 14 Unit Sizes...
Страница 34: ...34 Fig 63 Typical Humidi MiZer Adaptive Dehumidification System Humidistat Wiring 50TC 16 Unit Sizes HUMIDISTAT...
Страница 50: ...50 Fig 73 50TC 16 Control Box Component PremierLink Locations...
Страница 51: ...51 Fig 74 Typical PremierLink Control Wiring Diagram...
Страница 52: ...52 Fig 75 Typical PremierLink Control Wiring Diagram with Humidi MiZer System Option...
Страница 64: ...64 Fig 106 Typical RTU Open Controller Wiring Diagram 50TC 08 14 Size Units...
Страница 65: ...65 Fig 107 Typical RTU Open Controller Wiring Diagram 50TC 16 Size Unit...
Страница 66: ...66 Fig 108 Typical RTU Open Controller Wiring Diagram with Humidi MiZer System Option 50TC 08 14 Size Units...
Страница 67: ...67 Fig 109 Typical RTU Open Controller Wiring Diagram with Humidi MiZer System Option 50TC 16 Size Units...