OPERATING

 

INSTRUCTIONS

 

 

continued

 

 

When

 

the

 

pellets

 

have

 

ignited

 

and

 

flame

 

has

 

been

 

established,

 

the

 

start

up

 

cycle

 

will

 

end;

 

this

 

procedure

 

takes

 

between

 

8

 

and

 

12

 

minutes.

  

If

 

the

 

control

 

is

 

set

 

to

 

Manual

 

Mode,

 

it

 

will

 

now

 

default

 

to

 

the

 

heat

 

level

 

setting

 

the

 

last

 

shutdown

 

time.

  

If

 

the

 

control

 

is

 

set

 

to

 

T

STAT

 

Mode

 

the

 

heat

 

output

 

will

 

coincide

 

to

 

the

 

commands

 

from

 

the

 

thermostat.

 

 

Auger:

  

As

 

explained

 

in

 

the

 

starting

 

up

 

step,

 

this

 

button

 

is

 

only

 

served

 

to

 

start

 

up

 

the

 

pellet

 

stove

 

in

 

lieu

 

of

 

the

 

on/off

 

button

 

when

 

there

 

are

 

no

 

pellets

 

in

 

the

 

auger.

 

 

Circulation

 

Air

 

Flow:

 

Your

 

Pellet

 

Stove

 

Room

 

Heater

 

features

 

circulation

 

air

 

flow

 

which

 

will

 

change

 

in

 

accordance

 

with

 

the

 

heat

 

setting.

  

Circulation

 

air

 

flow

 

will

 

be

 

at

 

its

 

maximum

 

setting

 

when

 

the

 

heat

 

setting

 

is

 

also

 

at

 

maximum

 

and

 

subsequently

 

will

 

be

 

at

 

its

 

minimum

 

setting

 

when

 

the

 

heat

 

setting

 

is

 

at

 

minimum.

 

If

 

you

 

desire

 

to

 

operate

 

the

 

circulation

 

fan

 

at

 

its

 

maximum

 

setting

 

regardless

 

of

 

heat

 

setting,

 

you

 

may

 

do

 

so

 

by

 

pressing

 

the

 

FAN

 

button.

 

 

Auger

 

Trim:

 

When

 

operating

 

at

 

Heat

 

Level

 

1,

 

if

 

the

 

flame

 

goes

 

out

 

or

 

the

 

heat

 

output

 

is

 

too

 

high

 

on

 

the

 

minimum

 

heat

 

level

 

setting,

 

use

 

the

 

AUGER

 

TRIM

 

button

 

to

 

make

 

adjustments.

 

See

 

the

 

AUGER

 

TRIM

 

button

 

description

 

on

 

page

 

11.

 

 

Shutting

 

Down

 

Your

 

Pellet

 

Stove

 

Room

 

Heater:

  

Turn

 

off

 

the

 

heater

 

by

 

pressing

 

the

 

On/Off

 

button.

 

The

 

stove

 

will

 

enter

 

the

 

shutdown

 

cycle

 

and

 

the

 

pellets

 

will

 

stop

 

feeding

 

into

 

the

 

burn

 

pot

 

to

 

allow

 

the

 

fuel

 

in

 

the

 

burn

 

pot

 

to

 

be

 

combusted

 

and

 

consumed.

 

During

 

this

 

period,

 

the

 

exhaust

 

blower

 

and

 

circulation

 

fan

 

will

 

continue

 

to

 

operate

 

until

 

the

 

flames

 

are

 

out

 

and

 

the

 

heater

 

has

 

cooled

 

down.

  

When

 

the

 

heater

 

has

 

cooled

 

down

 

to

 

its

 

pre

set

 

level,

 

it

 

will

 

shut

 

down

 

completely.

 

 

CAUTION:

 

NEVER

 

TURN

 

OFF

 

THE

 

HEATER

 

BY

 

UNPLUGGING

 

OR

 

DISCONNECTING

 

ITS

 

ELECTRICAL

 

POWER

 

SOURCE.

 

DOING

 

SO

 

WILL

 

CAUSE

 

THE

 

HEATER

 

TO

 

SKIP

 

THE

 

PROPER

 

SHUTDOWN

 

CYCLE,

 

CAUSING

 

THE

 

HEATER

 

TO

 

OVERHEAT

 

AND

 

THE

 

POSSIBLE

 

RELEASE

 

OF

 

SMOKE

 

INTO

 

THE

 

HOUSE.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PELLET 5660(I)

Страница 1: ...may result For everyone s safety FOLLOW all Installation and Operating Directions Never use makeshift compromises during the installation of this appliance Contact your local building or fire official...

Страница 2: ...ting Instructions 8 11 Thermostat Installation 12 Clearances to Combustibles 13 Installing Your Room Heater 14 23 Mobile Home Installations 24 Insert Pellet Stove Installation 25 28 Vent Termination L...

Страница 3: ...meter by 1 1 2 length Ash Content 1 Maximum Premium grade 3 Maximum Standard grade Moisture Content 8 Maximum Heat Content Minimum 8 200 btu s per hour It is important to note that the ash content of...

Страница 4: ...e is maintained Make sure that structural integrity of the home is maintained when passing vent pipes through walls ceilings and roofs It is recommended that the exhaust vent be cleaned bi annually or...

Страница 5: ...ower outages with battery backup or room air starvation occurs during operation of heater smoke in the house may result This may trigger smoke detectors if they are installed CAUTION DO NOT CONNECT TO...

Страница 6: ...6 SPECIFICATIONS Heating Specifications Burn Rate 43 900 btu s per hour or 5 1 lbs of fuel per hour Hopper Capacity 55 lbs Dependent upon quality and heating value of pellet fuel DIMENSIONS Figure 1...

Страница 7: ...7 DIMENSIONS continued The minimum installation dimensions of the insert opening are 32 813mm wide x 22 3 4 578mm high x 12 1 4 311mm deep Figure 2...

Страница 8: ...d you will feel the latch engage and hear an audible click When first operating your Pellet Stove depress the MODE button until the LED indicator above MANUAL lights up This will engage MANUAL mode an...

Страница 9: ...u desire to operate the circulation fan at its maximum setting regardless of heat setting you may do so by pressing the FAN button Auger Trim When operating at Heat Level 1 if the flame goes out or th...

Страница 10: ...will end this takes between 8 12 minutes At this point the LED indicator light above the ON OFF button will glow solid green The user will now be able to make heat level adjustments HEAT LEVEL Button...

Страница 11: ...t accidental injury KEEP PELLET FUEL HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING DO NOT OVERFILL HOPPER Safety Features and warning code 1 Your heater is equipped with a temperature high limi...

Страница 12: ...wires and connect to the screw terminal on the rear of the control panel see Figure 4 If you have installed a remote thermostat for your pellet stove and wish to have the heater controlled by that the...

Страница 13: ...stalled on a combustible floor it is mandatory that a 1 2 13mm thick non combustible hearth pad be installed under the heater The non combustible hearth pad must extend at least 6 beyond the fuel load...

Страница 14: ...sectional area of over 28 square inches 711mm2 Venting can pass through the ceiling and roof if approved pipe is used Where passage through a wall or partition of combustible construction is desired t...

Страница 15: ...ir vent has an approved cap on it to prevent rodents from entering Be sure to install in location that won t become blocked with snow etc 8 The air intake pipe is equipped with a butterfly valve that...

Страница 16: ...16 INSTALLING YOUR ROOM HEATER continued HORIZONTAL EXHAUST VENT INSTALLATION...

Страница 17: ...r of the combustion air intake pipe at the back of your unit Line up the center with the same spot on your exterior wall and cut a 2 1 2 64mm diameter hole through the wall 5 Secure all vent joint con...

Страница 18: ...the wall 5 Secure all vent joint connections with 3 screws Seal the exhaust vent joint connections with high temperature silicone sealant 6 Locate the center of the exhaust pipe at the back of the un...

Страница 19: ...19...

Страница 20: ...20 INSTALLING YOUR ROOM HEATER continued SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET STOVE HEATERS Images courtesy of Selkirk...

Страница 21: ...21 INSTALLING YOUR ROOM HEATER continued SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET STOVE HEATERS Images courtesy of Selkirk UP OUT HORIZONTAL TERMINATION KIT Figure 12...

Страница 22: ...22 INSTALLING YOUR ROOM HEATER continued SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET STOVE HEATERS Images courtesy of Selkirk STRAIGHT OUT HORIZONTAL TERMINATION KIT Figure 13...

Страница 23: ...23 INSTALLING YOUR ROOM HEATER continued SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET STOVE HEATERS Images courtesy of Selkirk THROUGH THE ROOF VERTICAL TERMINATION KIT Figure 14...

Страница 24: ...r person having jurisdiction on height restrictions In order for this unit to be installed in a mobile home the following criteria must be met The unit must be secured to the floor using lag bolts in...

Страница 25: ...of the fireplace There is a small amount of assembly required when installing this model The steps are as follows Note The shroud must be installed before unit is set into its final position Step 1 S...

Страница 26: ...k of the unit take the top shroud side piece and fasten as shown with 4 screws provided Step 4 Control Board Take the control board and insert it from the back of the right shroud side facing front of...

Страница 27: ...a k factor of 0 84 For multiple layers add R values of each layer to determine the overall R value The R value for the required board is 1 2 Convert specification to R value k factor is given with a r...

Страница 28: ...e adapter to the exhaust fan and either a 90 elbow or a clean out tee with cap The air intake can be attached to the heater with a hose clamp 6 Connect the heater to the coupling on the bottom of the...

Страница 29: ...29 VENT TERMINATION LOCATIONS Figure 22...

Страница 30: ...ol to room temperature before inspecting the burn pot Inspect the burn pot regularly to check that the holes have not become plugged If necessary clean thoroughly It is imperative that the burn pot be...

Страница 31: ...r vacuum cleaner should have a special filter or bag to eliminate leakage 5 Remove ash pan and dispose of ashes into metal container 6 Reinstall ash pan 7 Reinstall burn pot and burn pot liner Ash Rem...

Страница 32: ...on the blades of the circulation exhaust fans The fans should be inspected periodically and if any accumulation is present vacuumed clean as the ash or dust can impede the fans performance It is also...

Страница 33: ...ermine if cleaning is necessary Door Gaskets Gaskets around the door and window panes should be inspected cleaned and repaired when necessary to maintain good seal Door Glass Removal and Replacement D...

Страница 34: ...r local dealer for service Check the vacuum switch by shorting out the vacuum switch then depress ON OFF button to OFF and back to ON If the unit starts to operate change the vacuum switch Check the e...

Страница 35: ...ns If the auger motor starts to function normally replace the high limit switch If the auger is not jammed and you have tried the other possible causes connect 120 volts directly to the auger motor If...

Страница 36: ...runs constantly there is a problem with the circuit board Combustion blower is not operating Check the exhaust blower is operating if not bypass the exhaust temperature switch if the motor operates r...

Страница 37: ...37 WIRING DIAGRAM...

Страница 38: ...y 1 Microlite Glass ROBAX 5mm thick 2 High Temp Paint STOVE BRIGHT Aerosol can or brush bottle 3 Exhaust Blower J238 AC 115V 60HZ 1 5A 4 Circulation Blower F33HA AC 120V 60HZ 1 4A 5 Auger Motor 6120A1...

Страница 39: ...made under the terms of this warranty are warranted only for the remaining period of the original heater warranty 4 Without specific written exclusionary waivers no one has authority to add to or var...

Страница 40: ...40...

Отзывы: