27
INSERT
PELLET
STOVE
INSTALLATION
‐
continued
Minimum
Clearance
to
Combustibles
and
Floor
Protection
A
:
Side
wall:
16”
to
side
of
appliance
B
:
Top
Trim:
5”
above
top
of
appliance
C
:
Side
trim:
10.5”
to
side
of
appliance
D
:
Mantle:
10”
above
top
of
appliance
Floor
Protection
When
in
MASONRY
fireplaces
,
use
½
inch
thick
non
combustible.
When
in
Factory
‐
built
fireplaces,
use
a
1
inch,
non
‐
combustible
surface
with
a
k
factor
of
0.84.
For
multiple
layers,
add
R
‐
values
of
each
layer
to
determine
the
overall
R
‐
value.
The
R
value
for
the
required
board
is
1.2.
Convert
specification
to
R
‐
value:
k
‐
factor
is
given
with
a
required
thickness
(T)
in
inches:
R=1/k
x
T.
The
C
‐
factor
is
given:
R=1/C
Example:
If
the
floor
protector
is
4”
brick
with
a
C
‐
factor
of
1.25
over
1/8”
mineral
board
with
a
“k”
factor
of
0.29
the
total
R
‐
value
of
the
system
is:
4”
brick
C=1.25,
R=1/1.25=0.8
1/8”
mineral
board
K=0.29,
R=1/0.29
x
0.125=0.431
Total
R
=
Rbrick
+
Rmineral
=
0.8
+
0.431
=
1.231
Total
R
is
greater
than
1.2,
the
system
is
acceptable.
Figure
20
6