8
© 2023 Breckwell
INSTALLATION
hardening mastic. Slip the storm collar over the pipe,
and while holding the pipe at the proper elevation,
affix the collar with a minimum of 3-1/4” (83 mm)
stainless steel sheet metal screws. Seal all joints and
seams around the collar.
6. Connect the horizontal pipe by pushing it through the
hole in the masonry and lining it up with the branch in
the tee. Push the pipe into the tee while twisting it to
lock it into the tee.
7. If desired, once the horizontal pipe is in place, the
space between the pipe and masonry may be filled
with high-temperature grout.
8. Install the trim collar. An adjustable pipe length and
adapter may be needed to finish the connection to the
stove.
L-VENT OR OPTIONAL
3 OR 4 “ STAINLESS
STEEL SINGLE WALL
PIPE OR FLEX PIPE.
OPTIONAL
OUTSIDE AIR
TRIM COLLAR
6”
(153 mm)
3”
(77 mm)
NOTE: FOLLOW
METAL CHIMNEY
INSTALLATION
INSTRUCTIONS
TOP PLATE (SEAL
TO CHIMNEY TOP
WITH NON-
HARDENING
MASTIC)
EXTENSION TO
CHIMNEY TOP
REQUIRED
PIPE ADAPTER
CLEAN-OUT-TEE
(TYPE L)
VENTING YOUR PELLET STOVE INTO AN
EXISTING CLASS A 6” CHIMNEY SYSTEM
IMPORTANT:
IF YOU ARE INSTALLING YOUR PELLET STOVE AS A
REPLACEMENT TO AN EXISTING WOOD STOVE, YOU
CAN INSTALL YOUR PELLET STOVE USING THE EXISTING
CLASS A 6” VENTING SYSTEM.
1. You must have the existing chimney system cleaned
and/ or inspected by a qualified chimney sweep before
proceeding with the installation of your pellet stove.
2. To the right is an example of an installation using part
number 860001, 3-6” transition into 6” connector
pipe. The illustration is only an example. Please
conform to any local building codes or regulations
having jurisdiction before you have a qualified installer
proceed with this installation.
WARNING:
YOU MAY WANT TO LOCATE ANY UTILITIES OR
OBSTACLES INSIDE THE WALL BEFORE ATTEMPTING THIS
INSTALL. MAKE SURE TO KEEP IN MIND YOUR UNIT’S
CLEARANCE REQUIREMENTS.
1. Mark the area and then cut the wall for vent installation
if needed.
2. Install the wall thimble as specified by the manufacturer
(wall thimble sold separately)
3. Install venting.
Existing Class ‘A’
6” Chimney System
3” PL Vent
Clean Out Tee
Support
Bracket
Ceiling
Support
3” to 6” Pipe
Adapter
TO STOVE
ELECTRICAL INSTALLATION
This stove is provided with a 6-foot grounded electrical
cord extending from the rear of the stove. We recommend
connecting to a good quality surge protector that is plugged
into a standard three-prong, 120V, 60Hz electrical outlet.
Содержание SP1000E
Страница 2: ...Project 23 114 Model SP1000E Page 2 Revision History 6 14 2023 Original Issue...
Страница 11: ...Project 23 114 Model SP1000E Page 11 Appliance Front Appliance Left...
Страница 12: ...Project 23 114 Model SP1000E Page 12 Appliance Right Appliance Rear...
Страница 14: ...Project 23 114 Model SP1000E Page 14 Pellet Fuel Analysis...
Страница 17: ...Project 23 114 Model SP1000E Page 17 Sealed Unit...
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 110: ...24 2023 Breckwell REPLACEMENT PARTS 1 2 3 4 5 6 7 8 9 10 11 12 13 27 14 15 16 17 18 19 20 21 32 22 23 24 29 28 30 26 25...
Страница 113: ...2023 Breckwell 27 ITEMS DEFINED...
Страница 181: ......
Страница 182: ......
Страница 183: ......
Страница 184: ......
Страница 185: ......
Страница 186: ......
Страница 187: ......