Run Data.xlsm
PM
R
– Average particulate emissions for full integrated test run, g/hr
ASTM E2779 equation (5)
PM
R
= 60 (E
T
/
θ
)
Where,
E
T
= Total particulate emissions, grams
θ
= Total length of full integrated test run, min
Sample Calculation:
E
T
(Dual train average) =
6.09 g
θ
=
360 min
PM
R
= 60 x (
6.09 /
360 )
PM
R
=
1.02
g/hr