It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is 

completed.

SERVICE PROVIDER

Before completing the appropriate Service Record below, please ensure you have carried out the service as described in 

the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.

Service 01

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 03

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 05

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 07

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 02

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 04

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 06

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 08

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

SERVICE RECORD

Содержание Hot Blast HB1520

Страница 1: ...rea CAUTION Please read this entire manual before you install or use this unit Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void...

Страница 2: ...TOVE IN ADDITION YOU SHOULD HAVE YOUR CHIMNEY INSPECTED FOR CREOSOTE DEPOSTS MONTHLY DURING THE HEATING SEASON AND ANNUALLY INSPECTED AND CLEANED This manual describes the installation and operation o...

Страница 3: ..._________________________________________ If no Date of inspection of the existing chimney system ___________________________________________________________ COMMISSIONING Confirm Hearth Pad Installat...

Страница 4: ...rangement NOTE The firebricks are silicone into place to prevent damage from shipping Attempting to remove the firebricks before operation could result in damage CERAMIC FIBER BOARD CONFIGURATION Insp...

Страница 5: ...ter installation the smoke curtain should swing freely back into the furnace OUTSIDE VIEW OF THE UNIT INSIDE VIEW OF THE UNIT FEED DOOR HANDLE LATCH Use the included one 1 nut and one 1 washer to secu...

Страница 6: ...2 screws to secure the front cover hood to the unit as shown DISTRIBUTION BLOWERS WITH GASKETS Secure the two blowers and gaskets to the unit using the eight 8 provided 1 4 20 x 3 4 bolts JUNCTION BO...

Страница 7: ...redetermined length of approximately 3 feet FILTER BOX The filter box is made up of 4 parts plus all hardware necessary for assembly Assemble the filter box sides top and bottom using twenty 20 10 A x...

Страница 8: ...8 2023 United States Stove Company AIR FILTER REPLACEMENT Insert one 16 x 24 x 1 air filter not included ASSEMBLY INSTRUCTIONS...

Страница 9: ...NT INJURY DO NOT ALLOW ANYONE TO USE THIS FURNACE WHO IS UNFAMILIAR WITH THE CORRECT OPERATION OF THE FURNACE CAUTION GASES THAT ARE DRIVEN FROM FRESH WOOD MUST BE BURNED OR THEY WILL ACCUMULATE AND E...

Страница 10: ...supply air ductwork This furnace may be installed as a stand alone wood furnace only See installation section in this manual to ensure proper assembly installation and operation of your new furnace If...

Страница 11: ...built in compliance with the specifications of the National Building Code It must be lined with fire clay bricks metal or clay tiles sealed together with fire cement Round flues are the most efficien...

Страница 12: ...wall to a masonry chimney special methods are needed as explained in the Combustible Wall Chimney Connector Pass Throughs Section WARNING DO NOT CONNECT THIS FURNACE TO A CHIMNEY FLUE SERVING ANOTHER...

Страница 13: ...ed 1 25 4 mm off the chimney connector by way of sheet metal support plates at both ends of chimney section Cover opening with and support chimney section on both sides with 24 gage minimum sheet meta...

Страница 14: ...er on a smoke exhaust system is prohibited Do not use with a flue damper With a controlled combustion wood furnaces the draft is regulated upon intake of the combustion air in the furnace and not at t...

Страница 15: ...when burning air dried seasoned hardwoods as compared to softwoods or too green or freshly cut hardwoods The following resources can assist in learning the burn characteristics of various species of w...

Страница 16: ...this wood furnace in a manner inconsistent with operating instructions in this manual EFFICIENCIES Efficiencies can be based on either the lower heating value LHV or the higher heating value HHV of t...

Страница 17: ...the furnace the wall thermostat should be set to its MAX setting so that the combustion fan is ON Start the fire with approximately 12 lbs of kindling which will be several small strips of wood 1 1 2...

Страница 18: ...r in how well the thermostat can maintain it s set temperature VISIBLE SMOKE The amount of visible smoke being produced can be an effective method of determining how efficiently the combustion process...

Страница 19: ...CHIMNEYFOR CREOSOTE DEPOSITS AT LEAST MONTHLY DURING THE HEATING SEASON ANY ACCUMULATIONS SHOULD BE REMOVED COMPLETE CHIMNEY INSPECTIONS AND CLEANING SHOULD BE CONDUCTED ANNUALLY TYPICALLY THIS TASK S...

Страница 20: ...OR EVEN HOUSE FIRE MAY RESULT It is recommended that you change the door gasket which makes your furnace door air tight once a year in order to ensure good control over the combustion maximum efficien...

Страница 21: ...T FEW FIRES BUILD SMALL FIRES AT FIRST THE METAL USED IN CONSTRUCTION OF THE FURNACE AND DUCT WORK HAS A LIGHT COATING OF OIL THIS COULD GIVE OFF SMOKE AND OR ODOR FROM REGISTERS WHEN FURNACE IS USED...

Страница 22: ...22 2023 United States Stove Company ELECTRICAL INSTALLATION...

Страница 23: ...NTY To order parts Call 1 800 750 2723 Ext 5051 or Email to parts usstove com Key Part Description Qty 1 88126 DOOR GASKET 5ft 2 892686 DOOR GLASS 1 3 88087 GLASS GASKET 30 4 80697 MOISTURE METER 1 5...

Страница 24: ...ription Qty 1 88353 BAFFLE BLANKET 2 2 893927 TOP BAFFLE SET OF 2 1 3 893928 BOTTOM BAFFLE SET OF 2 1 4 88360 C CAST LARGE 10 5 88362 C CAST SMALL 2 6 88361 C CAST MEDIUM 2 7 893792 TRUNK ASSEMBLY 1 8...

Страница 25: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Страница 26: ...26 2023 United States Stove Company NOTES...

Страница 27: ...2023 United States Stove Company 27 NOTES...

Страница 28: ..._________________ Nom de l ing nieur ________________________________ No de licence ______________________________________ Entreprise ________________________________________ N de t l phone __________...

Страница 29: ...EUR JEU DE 2 1 3 893928 D FLECTEUR INF RIEUR JEU DE 2 1 4 88360 C CAST GRANDE 10 5 88362 C CAST PETIT 2 6 88361 C CAST MOYEN 2 7 893792 ASSEMBLAGE DU TRONC 1 8 88366 JOINT DE COFFRE 1 9 893806 DISPOSI...

Страница 30: ...z un courriel parts usstove com R f rence N de pi ce Description Qt 1 88126 JOINT D TANCH IT DE PORTE 5 pi 2 892686 VITRE DE PORTE 1 3 88087 JOINT D TANCH IT EN VERRE 30 po 4 80697 HUMIDIM TRE 1 5 807...

Страница 31: ...R GLAGE DES POINTEURS L I M I T E D U VE N T I L A T E U R A R R T A R R T M A R C H E CONTR LE DE LA LIMITE LIGNE DE LIMITE LIGNE DE VENTILATION Honeywell JAUGE EN BANDES CAVALIER DE COUPURE POUR LA...

Страница 32: ...ES D ABORD DE PETITS FEUX LE M TAL UTILIS DANS LA CONSTRUCTION DE LA FOURNAISE ET DU R SEAU DE GAINES A UNE L G RE COUCHE D HUILE CELA POURRAIT D GAGER DE LA FUM E ET OU UNE ODEUR DES REGISTRES LORSQU...

Страница 33: ...NCENDIE Il est recommand de changer le joint d tanch it de la porte assurant l tanch it la porte de la fournaise une fois par ann e afin de vous assurer un bon contr le sur la combustion une efficacit...

Страница 34: ...CR OSOTE DANS VOTRE CHEMIN E AU MOINS UNE FOIS PAR MOIS PENDANT LA SAISON DE CHAUFFAGE TOUTE ACCUMULATION DOIT TRE ENLEV E UNE INSPECTION ET UN NETTOYAGE COMPLETS DE LA CHEMIN E DOIVENT TRE EFFECTU S...

Страница 35: ...froides et la construction de votre maison isolation jouent un r le important dans la capacit du thermostat maintenir la temp rature fix e FUM E VISIBLE La quantit visible de fum e produite peut tre...

Страница 36: ...afin que le ventilateur de combustion soit en MARCHE Commencez le feu avec environ 12 livres de bois d allumage qui sera constitu de plusieurs petites lamelles de bois larges de 4 7 cm 1 1 2 2 1 2 po...

Страница 37: ...que inf rieur PCI ou le pouvoir calorifique sup rieur PCS du combustible Le pouvoir calorifique inf rieur c est lorsque l eau quitte le processus de combustion sous forme de vapeur dans le cas des po...

Страница 38: ...plus lev s et des missions plus faibles r sultent g n ralement de la combustion de bois feuillus s ch s l air par rapport aux bois tendres ou aux bois feuillus trop verts ou fra chement coup s Les re...

Страница 39: ...combustion dans la fournaise et non l vacuation CHEMIN E PR FABRIQU E L utilisation d une chemin e pr fabriqu e en m tal exige le respect des instructions d installation du fabricant Vous devez aussi...

Страница 40: ...e 15 24 cm 6 po Utilisez ceci comme passage mural pour un conduit de raccordement en m tal simple paroi d un calibre minimum 24 Gardez la section solid pak concentrique et espac e de 2 54 cm 1 po du c...

Страница 41: ...nt du mur combustible En utilisant une paisseur minimale de la brique de 89 mm 3 5 po et une paisseur minimale de la paroi du boisseau en argile de 15 9 mm 5 8 po construisez un manchon de raccordemen...

Страница 42: ...seau d argile r fractaire du m tal ou des tuiles d argile scell es ensemble avec un ciment r fractaire Les conduits ronds sont les plus efficaces Le diam tre int rieur du conduit de fum e doit tre ide...

Страница 43: ...l installation et le fonctionnement de votre nouvelle fournaise sont corrects En cas d installation dans une zone quip e d un ventilateur celui ci ne doit pas cr er de pression n gative dans la pi ce...

Страница 44: ...TTENTION LES GAZ PROVOQU S PAR LE BOIS FRAIS DOIVENT TRE BR L S SINON ILS S ACCUMULENT ET EXPLOSENT N TOUFFEZ JAMAIS UN FEU LORSQUE VOUS AJOUTEZ DU BOIS FRAIS DANGER RISQUE D INCENDIE OU D EXPLOSION N...

Страница 45: ...8 2023 United States Stove Company REMPLACEMENT DU FILTRE AIR Ins rez un filtre air 16 24 1 non inclus INSTRUCTIONS D ASSEMBLAGE...

Страница 46: ...une longueur pr d termin e d environ 1 m tre 3 pi BO TIER DE FILTRE Le bo tier de filtre est compos de 4 pi ces plus tout le mat riel n cessaire l assemblage Assemblez les c t s le haut et le bas du b...

Страница 47: ...le capot avant l appareil comme illustr VENTILATEURS DE DISTRIBUTION AVEC JOINTS D TANCH IT Fixez les deux sou antes et les joints l unit l aide des huit 8 boulons 1 4 20 3 4 fournis SUPPORT DE BO TE...

Страница 48: ...Apr s l installation l cran de cantonnement doit pouvoir balancer librement vers la fournaise VUE EXT RIEURE DE L UNIT VUE INT RIEURE DE L UNIT POIGN E ET LOQUET DE LA PORTE D ALIMENTATION Utilisez un...

Страница 49: ...one pour viter tout dommage pendant le transport Tenter de supprimer les briques r fractaires avant l utilisation peut entra ner des dommages CONFIGURATION DU PANNEAU EN FIBRE C RAMIQUE Inspectez s il...

Страница 50: ...que _________________________________ Si non date d inspection du syst me de chemin e existant ________________________________________________________________ MISE EN SERVICE Confirmez l installation...

Страница 51: ...VOUS DEVEZ AUSSI PROC DER L INSPECTION DE VOTRE CHEMIN E POUR D TECTER LES D P TS DE CR OSOTE UNE FOIS PAR MOIS PENDANT LA SAISON DE CHAUFFAGE ET UNE FOIS PAR AN POUR UN CONTR LE ET UN NETTOYAGE Ce ma...

Страница 52: ...z enti rement ce manuel avant d installer ou d utiliser cette unit Ne pas respecter ces instructions pourrait causer des dommages la propri t des blessures corporelles ou m me la mort Une installation...