Ultra Moto VR Manual
03/03/2020
26
7.2 Troubleshooting
Troubleshooting
Possible Cause
Influence
Recommended action
AC IS OFF
Air compressor
power supply is off
1. Motion
platform will not
move
2.Motion platform
calibration fail.
3.Motion platform
activate fail.
1. Check and reconnect the
loose cable on the middle
cabinet
2. If no jet sound is heard
when power on the machine,
change the air compressor
power supply.
MOTION
PLATFORM OFF
Motion off
Motion platform
will not move
Press STOP button to open
motion.
ADJUSTMENT
ERROR
1.Air compressor
power supply is off
2.STOP button is on
3.The air pressure
of the Air
compressor is not
0.25MPa
4.Air compressor
cable faulty
Motion platform
will not move or
move faulty
1.Press Test to enter the Main
menu. Select [System
Settings] → [VR Headset
Environment Setting](Refer to
8.14.3)
2.Check whether solenoid
valve is faulty.
3.Check whether Height
sensor is faulty.
PLATFORM
ERROR
1.Air compressor
power supply is off
2.STOP button is on
3.The air pressure
of the Air
compressor is not
0.25MPa
4.Air compressor
cable faulty
Motion platform
will not move
Check whether Height sensor
is faulty.
I/O1 ERROR
Cannot identify I/O
1 board signal
Gas, brake,
leaning, speaker
and lighting,
seating security
sensor, headset
storage detection
,
platform lighting
and air
compressor SW
signal will not
work.
1.Check whether I/O 1 board
is faulty.
2.Check whether fuse board
is faulty.
I/O2 ERROR
Cannot identify I/O
2 board signal
Motion platform,
STOP button,
pedal sensor,
pedal light and
jack mechanism
will not work.
1.Check whether I/O 1 board
is faulty.
2.Check whether fuse board
is faulty.
Содержание Ultra Moto VR
Страница 1: ...IMPORTANT Operation Manual...
Страница 78: ...Ultra Moto VR Manual 03 03 2020 77 9 27 Decal...
Страница 80: ...Ultra Moto VR Manual 03 03 2020 79...
Страница 90: ...Ultra Moto VR Manual 03 03 2020 89 10 3 Overall Construction...
Страница 95: ...Ultra Moto VR Manual 03 03 2020 94 10 7 Gas Circuit Elementary Diagram...