87
9
RS-485 INTERFACE
87
R
S-
48
5
IN
TE
R
FA
C
E
Chapter
9
*1: WEIGHT ERROR
OFL1, OFL2, -OFL2, OFL3, LOAD, -LOAD, and ZALM are included.
*2: Status 1
- Decimal place:
Shows decimal place.
- Unit:
Shows unit.
- -OFL2, OFL2, -LOAD, +LOAD, ZALM:
"1" when each error occurs.
- Calibration processing condition:
"1" during zero calibration or span calibration.
- Calibration error:
Shows the error No. of the calibration error that has occurred.
"0" means that no calibration error is given.
Decimal place
Bit No.
9
8
None
0
0
0.0
0
1
0.00
1
0
0.000
1
1
Unit
Bit No.
12
11
10
None
0
0
0
t
0
0
1
g
0
1
0
kg
0
1
1
lb
1
0
0
Cal. err
Bit No.
7
6
5
4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
-LOAD
+LOAD
ZALM
Unit (0 - 4)
Decimal place (0 - 3)
Calibration error (0 - 9)
Calibration processing condition
RESERVE