6.DISCHARGING CONTROL MODE
84
Example)
Final
20.000
AFFC.
0.100
Average count of AFFC.
4
AFFC. coefficient
2/4
* When Compensation value is changed, average count of AFFC. becomes 0.
Times
Actual
Weighing
Error
Average count of
AFFC.
CPS
When negative CPS
is inhibit.
When negative CPS
is effect.
0
0
←
Power ON
1
20.050
+0.050
1
0.500
-0.033
2
20.040
+0.040
2
0.500
-0.033
3
20.070
+0.070
3
0.500
-0.033
4
20.080
+0.080
4
→
0
0.500
-0.033
+0.240/4 = 0.060
0.060×2/4 = 0.030
→
CPS Value
5
20.020
+0.020
1
0.530
-0.003
6
20.000
0.000
2
0.530
-0.003
7
20.010
+0.010
3
0.530
-0.003
8
20.110
(+0.110)
←
×3
0.530
-0.003
9
20.010
+0.010
4
→
0
0.530
-0.003
+0.040/4 = 0.010
0.010×2/4 = 0.005
→
CPS Value
10
19.880
(-0.120)
←
×1
0.535
0.002
11
19.990
-0.010
1
0.535
0.002
12
20.010
+0.010
2
0.535
0.002
13
20.000
0.000
3
0.535
0.002
14
19.980
-0.020
4
→
0
0.535
0.002
-0.020/4 = -0.005
-0.005×2/4 = -0.003
→
CPS Value
0.532
-0.001
Setting compensation coefficient
Compensation coefficient can be selected from 1/4, 2/4, 3/4, or 1.
You can get more accurate compensation value by selecting 1 when each
weight value is approximate same in each measuring or by selecting 1/4 ~ 2/4
when each weight value fluctuates in each measuring.