6.DISCHARGING CONTROL MODE
78
①
Normal sequence control (with Over/Under judgment)
●
The completion signal output timing depends on the complete signal output mode setting
(Weighing Function 2 in setting mode 2).
●
The Over/Under comparison timing is such that the Over/Under comparison mode setting
(Weighing Function 2 in setting mode 2) is ignored, but comparisons are made when the
completion output is ON, and the weight value is held.
●
Upper/Lower limit comparison is always made in defiance of the setting of Upper/Lower limit
comparison mode (Weighing Function 2 in setting mode 2).
0
NET
Over
Under
TIME
Start
Stop
Complete
Judgment (Over, Go or Under)
ON
ON
OFF
Complete Timer
t3
ON
ON
ON
ON
t2
t1
t1
HOLD
Near Zero
Final – SP1
Final – SP2
Final – CPS
Final
SP2
SP1
SP3
Judging Timer
Near Zero
Tare Subtraction
Comparison
Inhibiti Timer
Содержание F701-C