7. Select option “3” at the prompt, enter the board’s new IP address based on the configuration you are using:
If the board is connected to the local host system through a crossover cable:
Use your host system’s IP address,
incremented by one, in the final position. For example, if the host system’s IP address is “169.225.150.10” enters
“
169.225.150.11”.
If the board is connected to a fixed address network:
Use the IP address assigned by your system administrator.
Press <ENTER>.
8. Select option “8” to disable DHCP. This menu will configure the board to use the manually assigned IP address. If
DHCP is disabled, text for option “8” will change to: “
8: Enable DHCP & IP Gleaning: DHCP is Currently disabled
”
To re-enable DHCP, select option “8”.
9. Select option “0” to save changes and quit.
10. In the
PCOM
board reconfigure the switch “BAUD RATE” as shown on (Figure 8), and restart
PCOM
board.
on
1
BAUD RATE
SW2
Figure 8
11. Close the terminal session. For your convenience, you may save the terminal session when prompted. You are now
ready to communicate with the board.
1.4.6.2 Display IP address
The IP address assigned by the server to
PCOM
card is displayed on the LCD display charger (Figure 9).
Display
example:
30V
.150
.1
168
.
192
#
10A
Содержание ARR-M Series
Страница 2: ... i BATTERY CHARGER USER S MANUAL ...
Страница 5: ... iv FIGURE LIST 86 ACRONYM LIST 88 LCD MESSAGES LIST 90 APPENDIXES 92 ...
Страница 6: ...MCEnPC23 REV 2 4 Page 1 PART 1 INSTALLATION INSTALLATION ...
Страница 10: ...MCEnPC23 REV 2 4 Page 5 PART 2 THEORY OF OPERATION THEORYOFOPERATION ...
Страница 98: ...Page 1 of 39 Rev 13 Communication User Manual Appendix 3 27 01 2015 ...