FOODBOX TOUCH, FOODBOX LONG TOUCH, FOODBOX LIFT TOUCH
Page 41
Version 1.3 / December 2018
SETTING
DESCRIPTIoN
VALUE
Sensor 1...3 min temp.
Sensor 1...3 max temp.
The setting of the temperature range, going be-
yond of which is considered an error. When spec-
ifying identical values for minimum and maximum
temperature the errors of the corresponding sen-
sor are deactivated. The ranges specified in this
setting should be min. 2 degrees wider than the
cooling unit settings (e.g., if the cooling unit is set
to retain the temperature of sensor 1 in the range
from 4 to 10, then the control temperature should
be specified in the range from 2 to 12 or even wid-
er). These settings have no effect on the cooling
unit operation. The range specified for sensor 1,
together with the (
Compressor control
) setting
(see below), is used for blocking the products,
for which the storage temperature conditions are
important. To disable such a control one should
specify identical minimum and maximum values
for the sensor 1. Sensor 1 is a temperature at the
bottom of the storage bay (cold zone). Sensor
2 is a temperature at the top of the storage bay
for regular vending machines or a temperature
of control compartment for FoodBox Street out-
door vending machines. Sensor 3 is an evapora-
tor temperature (an element that cools down the
vending machine cabinet).
Sensor 1...3 min temp.
- the setting of minimum
temperature for sensors No.1..3 of the vending
machine, upon reaching which the record will be
saved in the vending machine log.
Sensor 1...3 max temp.
- the setting of maximum
temperature for sensors No.1..3 of the vending
machine, upon reaching which the record will be
saved in the vending machine log.
Compressor control
This setting selects the type of the cooling unit
installed into the vending machine.
For the vending machines (with an autonomous
cooling unit, not connected to the vending ma-
chine electronics) and for the vending machines
without a cooling unit select the
Hardware
option.
For the FoodBox vending machines with a cooling
unit select the
Software (triac)
option.
For the FoodBox Street outdoor vending ma-
chines (in which, besides the cooling unit, there’s
a control compartment heater, as well as a tem-
perature sensor 2 that is installed not at the top
of the product storage compartment, but in the
control compartment) select the
outdoor
option.
Software (triac)
Hardware (danfos)
Outdoor
Max duration for temp 1 out of range
Specifies how many hours in succession the sen-
sor 1 temperature should be out of norm (which
is defined by
Sensor 1 min temp.
and
Sensor 1 max temp.
settings so that the fresh products storage error
is settled down (when the error settles down the
products marked as fresh are blocked). This error
after it settles can be reset via the menu (telem-
etry). To cancel this error disable the sensor 1
monitoring in the
Sensor 1 min temp.
and
Sensor
1 max temp.
setting (set identical values for mini-