8 UNIBLOC-PD Operation & Service Manual: PD600-677
unless it is assembled with a flushed shaft seal that is properly installed with a fully operational flushing system.
Installation of pressure gauges/sensors in conjunction with the pump’s suction and discharge connec
-
tions is recommended to be able to monitor the pumps pressure.
When cleaning manually or by CIP, SIP methods, the operator must
ensure that a suitable procedure is used in accordance with the systems
requirements.
If operating with a pulley, proper support must be selected to prevent
excessive bearing wear and bending of the shaft. See fig. 2.5. Additional
safety guards are a must.
3.0 Installation
3.1 Handling and Storage
Caution must be taken when lifting the pump or pump unit. For all parts over 20kg (44lbs) we recommend the
use of a lifting device or lifting arrangement when unpacking or moving. Check the weight guide in section 6.0
for details. See fig. 3.1 and 3.2 for lifting guidance. For large pumps, lifting eyes will be supplied with the pump
to assist in lifting/moving.
When you receive your product please follow these steps:
•
Check packaging for any damage in transit
•
Check the packing slip against received goods
•
If an assembly, make sure the manual for the drive unit is included
•
Visually inspect the product for any signs of damage
•
Report any damage immediately to the carrier
If installation of the pump is delayed, store and protect the unit properly by:
•
Not removing plastic port protectors.
•
Selecting a clean, dry storage location free from vibration. In a moist or dusty atmosphere, further protect the
pump/assembly with suitable cover.
fig. 2.5
Vertical Port Mounting
Horizontal Port Mounting
fig. 3.1
Horizontal Port Mounting
Vertical Port Mounting
fig. 3.2