Illustration 4 : Reducing random noise of signals
If the signal being measured is stacked with random noise, you can adjust the setups of
your oscilloscope to filter or reduce the noise, so it will not cause interference to the
signal during measurement. (Waveform is shown below)
Figure 3-4 Reducing random noise of signals
Steps :
1.
As in the previous illustration, set the attenuation factor of the probe and CH1.
2.
Connect the signal to ensure stable display of waveform.
See the previous
illustration for operation instruction. See the previous chapter for guidance on
adjusting the horizontal time base and vertical range.
3.
Improving trigger by setting trigger coupling
.
(1) Press [MENU] in the trigger zone to display the trigger setup menu.
(2) Set trigger coupling to low frequency suppression or high frequency suppression. By
selecting low frequency suppression a high-pass filter is set up. It filters low
frequency signal quantities under 80kHz and allows high frequency signal quantities
to pass through. If you select high frequency suppression a low-pass filter is set up.
It filters high frequency signal quantities higher than 80kHz and allows low
frequency signal quantities to pass through. By setting low frequency suppression or
high frequency suppression, you can suppress low frequency or high frequency noise
respectively and achieve a stable trigger.
4.
Reducing display noise by setting the acquisition mode.
c
If the signal being measured is stacked with random noise and the waveform is too
coarse as a result, you can use the average acquisition mode to eliminate random
noise display and reduce the size of waveform for easy observation and
measurement. After getting the mean, random noise is reduced and details of the
signal are clearer. Follow the steps below :
Press [ACQUIRE] in the control zone of the front panel to display the sampling
setup menu. Press [F1] then [F3] to set acquisition mode to ADVERAGE, then turn
the multifunction control knob to adjust the average number of times in multiples of
2, i.e. 2 to 256, until you get the desired waveform display that meets observation
and measurement requirements. (See the figure below)
Содержание UT4000 Series
Страница 13: ...2 UNI T UT4000 User Manual Figure 1 1 Front panel of UT4000 Oscilloscopes ...
Страница 14: ...3 UNI T UT4000 User Manual Figure 1 2 Schematic diagram for operating the UT4000 front panel ...
Страница 15: ...4 UNI T UT4000 User Manual Figure 1 3 Schematic diagram for the display interface ...
Страница 74: ...63 Figure 3 14 Dual time base function ...
Страница 98: ...87 UNI T UT4000 User Manual This user manual may be revised without prior notice ...