41
/
99
7.8 Delay Trigger
Delay trigger should set trigger source 1 and trigger source 2. When the time difference (
△
T) between
the edge set by source 1 (edge 1) and the edge set by source 2 (edge 2) meets the preset time limit, the
oscilloscope is triggered, as shown in Figure 7-5.
Figure 7-5
Edge 1 set as rising edge, edge 2 also set as rising edge.
△
T is the area marked by red color, as shown
in Figure 7-5.
Note
:
Edge 1 and edge 2 must be adjacent edges
.
Note
:
Only the channel that has been connected to the signal, select it as the trigger source that can get
the stable trigger.
(1) Condition
Set delay condition to
>
,
<
,
<>
,
≤≥
,
><
.
a.
>:
It will be generated when the time difference (
△
T) between the edge of source 1 and the
edge of source 2 is greater than the setting lower limit of time, it can set the lower limit of time.
b.
<:
It will be generated when the time difference (
△
T) between the edge of source 1 and the
edge of source 2 is smaller than the setting upper limit of time, it can set the upper limit of
time.
c.
≤≥:
It will be generated when the time difference (
△
T) between the edge of source 1 and
the edge of source 2 is greater than the setting lower limit of time and smaller than the setting
upper limit of time, it can set the upper limit and lower limit of time.
d.
>
<
( irrelevance)
:
It will be generated when the time difference (
△
T) between the edge of
source 1 and the edge of source 2 is smaller than the setting lower limit of time or greater than
the setting upper limit of time. It can set the upper limit and lower limit of time.
△
T
Содержание UPO1000CS Series
Страница 1: ...UPO1000CS SeriesDigital Phosphor Oscilloscope User s Manual REV 1 2022 11 11 ...
Страница 11: ...11 99 ...
Страница 90: ...90 99 15 Additional Function Key 15 1 Auto Setting 15 2 Run Stop 15 3 Factory Setting ...
Страница 93: ...93 99 16 System Prompt and Troubleshooting 16 1 Description of system prompt 16 2 Troubleshooting ...