background image

Tel: 888-990-7469

Tel: 888-990-7469

10

Uni-P H20 200C DEHUMIDIFIER

Installation, Operation & Service Instructions

Uni-P H20 200C DEHUMIDIFIER

Installation, Operation & Service Instructions

11

Maintenance

WARNING:

 You should never operate the Uni-P H2O 200CC dehumidifier with a less 

effective filter or without a filter. In any case, the heat exchange coils that are in the unit 

could get clogged and end up with disassembly need to clean. Also, using the device with 

a non-compliant filter invalidates the warranty. 

Standard Air Filter

Normally, the dehumidifier is shipped with a standard MERV 11 which is a filter made of pleated 

fabric. The filter may only require service after six months of use. If you operate the unit with a 

not-reliable filter you will deter the efficiency and capacitor of the entire dehumidifier and this 

mistake may result in the unnecessary cycling on and off while on the defrost control state. 

In order to access the air filter, you will have to remove the filter access panel first. On 

removing the filter access panel the filter should be easily seen and may be removed by just 

pulling it straight from the dehumidifier. It is advisable that you change the impeller after at 

least every grow cycle. 

The Impeller Fan Oiling

In most cases, the impeller fan is factory lubricated and this can serve several years of operation, 

and no further oil may be required. 

Dehumidifier Spare Parts

Fan Components

 External Components

N-100

N-101

N-102

N-1209

N-1206

N-1208

N-1207

Main Control Board

Display Board

RH/Temp. Sensor

Fan Motor

Complete Fan Assembly

Fan Capacitor

N-1210

N-1211

N-1205

N-1200

N-1201

N-1202

N-1203

N-125

Prefilter

MERV 8

HEPA

Carbon Filter

Foot adjustable

Display/Control

Inernal Components

Compressor

Compressor Capacitor

Coil Assembly

Condensate Pump

Assembly

Condensing Unit Spare Parts

Fan Components

 External Components

N-100

N-101

N-102

N-1209

N-1206

N-1208

N-1207

Main Control Board

Display Board

RH/Temp. Sensor

Fan Motor

Complete Fan Assembly

Fan Capacitor

N-1210

N-1211

N-1205

N-1200

N-1201

N-1202

N-1203

N-125

Prefilter

MERV 8

HEPA

Carbon Filter

Foot adjustable

Display/Control

Inernal Components

Compressor

Compressor Capacitor

Coil Assembly

Condensate Pump

Assembly

Содержание H20 200C

Страница 1: ...Uni P H20 200C Dehumdifiers Installation Operation Service Instructions Add 4240 Latham Street Suite D Riverside CA 92501 Tel 888 990 7469 E mail sales unipdry com READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...a way that it is suitable for indoor installation in a room that is perfectly protected from flooding and rain Always connect your dehumidifier using a grounded dedicated electrical connection that is...

Страница 3: ...trip circuit monthly the operation sales unipdry com 4 Warranty Registration Prior to installation of the unit write down the serial number and date of purchase You will need this information if you...

Страница 4: ...control panel in the central area of the room where it will be able to sense the RH of the room on turning it on It is important to install the remote control panel in the central area of the room wh...

Страница 5: ...l a cause a nuisance Vibration dampening material may be installed between the condensing unit base and the mounting pad if required Allow sufcient clearance to handle the unit s overall dimensions Pl...

Страница 6: ...ed from the manufacturer pressurized with the charge of inert gas together with a rubber plug in the lines You can purge the inert gas out of the device by simply removing the rubber plugs present in...

Страница 7: ...cylinder of the HFC 410A refrigerant in such a way that it delivers vapor only Open the valves on the refrigerant and ensure that the HFC 410A amount is at a maximum of 57g two ounces of refrigerant...

Страница 8: ...ressure manifold gage set sides from the valve removal tools Finally install the valve core present in the liquid and gas line port by simply using the no loss valve removal tool The On Board De humid...

Страница 9: ...g the filter access panel the filter should be easily seen and may be removed by just pulling it straight from the dehumidifier It is advisable that you change the impeller after at least every grow c...

Страница 10: ...469 to receive a Return Authorization RA number 3 Once an RA has been issued it is the customer s job to bring the unit to a certified repair center If this is not an option shipping will be arranged...