Uni-P H20 200C DEHUMIDIFIER

Installation, Operation & Service Instructions

Uni-P H20 200C DEHUMIDIFIER

Installation, Operation & Service Instructions

How it Works

Installation Requirements

Installation 

Key Functions

Indicator Lights

Remote Control

Operating Instructions

Unit Diagram

Maintenance

Important Notes

Warranty Registration

Specifications

Dehumdifier Storage

Ducted Applications

Troubleshooting

Spare Parts

14

Warranty Information

15

13

12

12

9

9

8

7

6

4

4

3

3

3

2

2

Install dehumidifier according to all applicable local

state

and national codes.

Ensure that the discharge air is not directed at people, or over water in spa and pool areas.

The condensing unit must always be protected from elements such as snow, rain, and 
sunlight although the device can be installed outdoors. 

If the device is meant for use near water, spa or a pool, make sure that there are no possible 
chances of the unit being splashed or/and falling into the water. Also, make sure that it is plugged 
into an outlet that is protected by the GFI (Ground Fault Interrupt) circuit. 

This type of dehumidifier is designed in such a way that it is suitable for indoor installation 
in a room that is perfectly protected from flooding and rain. 

Always connect your dehumidifier using a grounded, dedicated electrical connection that is 
GFCI protected with at least 15 amp capacity.

The use of any other type of wiring will void your warranty.

1.Important Introduce

The Unip H20 200C is a split system dehumidifier with sensible cooling
that is integrated into the heating and cooling system to provide the
ultimate in comfort, health and property protection through:

• 

Dehumidification

• Sensible Cooling
• Fresh Air Ventilation (Optional)
• Air Filtration

The two-piece design allows the sensible heat load generated from
dehumidifying the house to be released in the outside condensing unit,
thus eliminating additional cooling and reducing air conditioner run time.

It is made with a low voltage control system. 

It has the R410A refrigerant, which is generally environmentally friendly. 

It features an auto-restarting operational system after power outages. 

It used the standard MERV-11, which offers superior air filtration. 

The device has a quiet operation. 

It is designed with a long life and high-efficiency impeller. 

It has an optimized and perfectly patented air-to-air heat exchanger. 

The device brags of industry-leading effectuality. 

4,300 BTU cooling. 

2.Features

3.Safety Notes

Содержание H20 200C

Страница 1: ...Uni P H20 200C Dehumdifiers Installation Operation Service Instructions Add 4240 Latham Street Suite D Riverside CA 92501 Tel 888 990 7469 E mail sales unipdry com READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...a way that it is suitable for indoor installation in a room that is perfectly protected from flooding and rain Always connect your dehumidifier using a grounded dedicated electrical connection that is...

Страница 3: ...trip circuit monthly the operation sales unipdry com 4 Warranty Registration Prior to installation of the unit write down the serial number and date of purchase You will need this information if you...

Страница 4: ...control panel in the central area of the room where it will be able to sense the RH of the room on turning it on It is important to install the remote control panel in the central area of the room wh...

Страница 5: ...l a cause a nuisance Vibration dampening material may be installed between the condensing unit base and the mounting pad if required Allow sufcient clearance to handle the unit s overall dimensions Pl...

Страница 6: ...ed from the manufacturer pressurized with the charge of inert gas together with a rubber plug in the lines You can purge the inert gas out of the device by simply removing the rubber plugs present in...

Страница 7: ...cylinder of the HFC 410A refrigerant in such a way that it delivers vapor only Open the valves on the refrigerant and ensure that the HFC 410A amount is at a maximum of 57g two ounces of refrigerant...

Страница 8: ...ressure manifold gage set sides from the valve removal tools Finally install the valve core present in the liquid and gas line port by simply using the no loss valve removal tool The On Board De humid...

Страница 9: ...g the filter access panel the filter should be easily seen and may be removed by just pulling it straight from the dehumidifier It is advisable that you change the impeller after at least every grow c...

Страница 10: ...469 to receive a Return Authorization RA number 3 Once an RA has been issued it is the customer s job to bring the unit to a certified repair center If this is not an option shipping will be arranged...