Tel: 888-990-7469
Tel: 888-990-7469
1
Uni-P H20 200C DEHUMIDIFIER
Installation, Operation & Service Instructions
Uni-P H20 200C DEHUMIDIFIER
Installation, Operation & Service Instructions
How it Works
Installation Requirements
Installation
Key Functions
Indicator Lights
Remote Control
Operating Instructions
Unit Diagram
Maintenance
Important Notes
Warranty Registration
Specifications
Dehumdifier Storage
Ducted Applications
Troubleshooting
Spare Parts
14
Warranty Information
15
13
12
12
9
9
8
7
6
4
4
3
3
3
2
2
Install dehumidifier according to all applicable local
,
state
,
and national codes.
Ensure that the discharge air is not directed at people, or over water in spa and pool areas.
The condensing unit must always be protected from elements such as snow, rain, and
sunlight although the device can be installed outdoors.
If the device is meant for use near water, spa or a pool, make sure that there are no possible
chances of the unit being splashed or/and falling into the water. Also, make sure that it is plugged
into an outlet that is protected by the GFI (Ground Fault Interrupt) circuit.
This type of dehumidifier is designed in such a way that it is suitable for indoor installation
in a room that is perfectly protected from flooding and rain.
Always connect your dehumidifier using a grounded, dedicated electrical connection that is
GFCI protected with at least 15 amp capacity.
The use of any other type of wiring will void your warranty.
1.Important Introduce
The Unip H20 200C is a split system dehumidifier with sensible cooling
that is integrated into the heating and cooling system to provide the
ultimate in comfort, health and property protection through:
•
Dehumidification
• Sensible Cooling
• Fresh Air Ventilation (Optional)
• Air Filtration
The two-piece design allows the sensible heat load generated from
dehumidifying the house to be released in the outside condensing unit,
thus eliminating additional cooling and reducing air conditioner run time.
It is made with a low voltage control system.
It has the R410A refrigerant, which is generally environmentally friendly.
It features an auto-restarting operational system after power outages.
It used the standard MERV-11, which offers superior air filtration.
The device has a quiet operation.
It is designed with a long life and high-efficiency impeller.
It has an optimized and perfectly patented air-to-air heat exchanger.
The device brags of industry-leading effectuality.
4,300 BTU cooling.
2.Features
3.Safety Notes