AP01-HD_rev.09_UK
25
2.
STOP: to stop the rotation of motor.
3.
LIMITS: it enables the following functions:
Disable Limits: to delete all set limits from motor’s storage;
Set East Limit: to store the limit position of East rotation;
Set West Limit: to store the limit position of West rotation;
Exit: to exit menu.
4.
PROGRAM.: it enables the following functions:
Mem. Pos. PR (xx): to store the satellite-dish position inside the motor’s programs;
Recall Pos.: to recall a command from motor’s program storage and start positioning;
Exit: to exit menu.
5.
DEFAULT: it enables the following functions:
Reset Motor: to activate the motor’s rotation and move it to position 0°;
Recalc. Sat Pos.: to recalculate satellite positions stored inside motor’s programs;
Exit: exit menu.
Press the
DiSEqC
key
to exit menu and go back to normal functioning.
4.8.3.1.
USE OF DISEQC SCR FUNCTION
Turning the shaft encoder, move the cursor to DiSEqC SCR item. Press
ENTER
.
Turning the shaft encoder again, select the kind of LNB to drive between “mono feed” and
“dual feed”. Press
ENTER
to confirm. The screen displays the submenu to select one of the
four fixed frequencies and 1 user’s defined to use the SCR mode:
•
SCR A : 1210 MHz
•
SCR B : 1420 MHz
•
SCR C : 1680 MHz
•
SCR D : 2040 MHz
•
SCR E : USER
Select the desired frequency turning the shaft encoder, then press
ENTER
to make the
instrument enter the SCR mode. The indication of the active satellite polarity is displayed.
In case of dual-feed mode, the indication of polarity is associated to satellite 1 or 2.
Possible selections on mono-feed mode are:
-
POL V (polarizzazione Verticale)
-
POL H (polarizzazione Orizzontale)
Possible selections on dual-feed mode are:
-
SAT 1 - POL V;
-
SAT 1 - POL H;
-
SAT 2 - POL V;
-
SAT 2 - POL H.