2
1.2 Specifications
Table 1.1 Product Specifications
Model
DTC-22
Discharge rate
50Hz
20L/min
60Hz
24L/min
Pressure achieved
1.0kPa
Motor
Single phase,
AC 100 V
(±10%)
Single phase
,AC 115 V
(±10%)
Single phase
,AC 200 V
(±10%)
Single phase
,AC 220 V
(±10%)
Single phase,
AC 230 V
(±10%)
50 W, 4P, with condenser-run thermal protection relay (automatic reset)
Rated current
1.3/1.3A
(50/60Hz)
1.2/1.32A
(50/60Hz)
0.73/0.65A
(50/60Hz)
0.6/0.72A
(50/60Hz)
0.6A
(50Hz)
Speed
1290/1560rpm
(50/60Hz)
1260/1580rpm
(50/60Hz)
1310/1610rpm
(50/60
Hz)
1275/1570rpm
(50/60Hz)
1270rpm
(50Hz)
Inlet and outlet piping
O.D.
Φ
10
×
I.D.
Φ
6(G1/4)
Weight
7.3kg
Air temperature
0
~
40
℃
Dimensions
(W refers to the distance
to the tip of the intake or
exhaust pipe)
142mm(W)
×
272mm(L)
×
202mm(H)
Over
Voltage Category
Ⅱ
Pollution Degree
2
Table 1.2 Product Specifications
Model
DTC-22K
Discharge rate
50Hz
20L/min
60Hz
24L/min
Pressure achieved
1.0kPa
Motor
Single phase,
AC 100 V
(±10%)
Single phase
,AC 115 V
(±10%)
Single phase
,AC 200 V
(±10%)
Single phase
,AC 220 V
(±10%)
Single phase,
AC 230 V
(±10%)
50 W, 4P, with condenser-run thermal protection relay (automatic reset)
Rated current
1.3/1.3A
(50/60Hz)
1.2/1.32A
(50/60Hz)
0.73/0.65A
(50/60Hz)
0.6/0.72A
(50/60Hz)
0.6A
(50Hz)
Speed
1290/1560rpm
(50/60Hz)
1260/1580rpm
(50/60Hz)
1310/1610rpm
(50/60Hz)
1275/1570rpm
(50/60Hz)
1270rpm
(50Hz)
Inlet and outlet piping
O.D.
Φ
9
×
I.D.
Φ
6(G1/4)
Weight
7.0kg
Air temperature
0
~
40
℃
Dimensions
(W refers to the distance
to the tip of the intake or
exhaust pipe)
125mm(W)
×
247mm(L)
×
184mm(H)
Over Voltage Category
Ⅱ
Pollution Degree
2