Construcción
Construcción
Construcción
Construcción
48
MK
MK
MK
MK STRUCTURE
STRUCTURE
STRUCTURE
STRUCTURE
5.1.11.
JACK WALER MK
The jack waler is studied for the stripping at a 250 mm distance from the supporting areas of the posts. These
areas have to be properly stiffened.
F = 360 kN (SLS)
F = 360 kN (SLS)
F = 360 kN (SLS)
F = 360 kN (SLS)
Technical properties of the Jack Waler MK:
m = 72.4
(kg/m) weight/m
A = 92.24 10
-4
(m
2
)
net section area (without holes)
Av
zz
=42.16 10-4 (m
2
) shear area
Av
yy
=62.90 10-4 (m
2
) shear area
I
yy
= 8590 10
-8
(m
4
)
moment of inertia
I
zz
= 5274 10
-8
(m
4
)
moment of inertia
W
elyy
= 687 10
-6
(m
3
)
Young's modulus
W
elzz
= 376 10
-6
(m
3
)
Young's modulus
f
y
= 355
(MPa) yield strength
The maximum permissible bending moment and shear force of the connection is:
8 bolts M24x60 8.8
Mmax
yy
(SLS) = 75 kNm
∼
45 % waler strength
Tmax
yy
(SLS) = 300 kN
8 bolts M24x60 10.9
Mmax
yy
(SLS) = 100 kNm
∼
60 % waler strength
Tmax
yy
(SLS) = 375 kN
T