Installation, Operation and Maintenance Manual
UFO
uk.ufosecurity.com
30
Tamper or wait 4 minutes.
5.
WALK TEST
: When the cover is closed, the sensor prepares for the coverage
test for 3 minutes. Set the trimmer to the minimum (the white screw above
the tamper button, its range varies from 4 to 15 metres). Move to the end of
the area to be protected and, with the LEDs off, move towards the sensor
checking for uW (microwave) detections via the GREEN LED. If the LED does
not light up, increase the range by turning the trimmer clockwise, repeat
the test until the required condition is obtained. N.B.: The range should be
adjusted to the minimum necessary, as the uW passes through walls and
an excessive range does not increase performance in the protected area.
The illumination of the red LED indicates infrared detection.
The
REMOTE CONTROL
has 4 buttons, each with a specific
function
and a series of specific acoustic sounds to confirm that the
command has been received by the fogger:
•
Armo Totale
(top left, closed padlock): 1 short and 1
long sound;
•
Disarmo
(top right, open padlock): 3 short sounds;
•
Armo Parziale
(bottom left, house symbol): 2 short and
1 long sound;
•
Anti-rapina
(bottom right, SOS inscription).
The
MAGNETIC SENSOR
can be placed on doors and
windows. It sends the alarm command to the fogger
when the contact is opened. Esso invia il comando
d’allarme al nebbiogeno all’apertura del contatto.
Содержание Basic L
Страница 2: ......
Страница 4: ...01 Declaration of conformity p 5 Manufacter data p 7 Presentation of the Manual p 8...
Страница 19: ......
Страница 47: ...Installation Operation and Maintenance Manual UFO 47 uk ufosecurity com PIN ILLUSTRATION...
Страница 49: ......
Страница 50: ...04 Maintenance p 50 Decommissioning p 52...
Страница 54: ...Installation Operation and Maintenance Manual UFO uk ufosecurity com 54...