background image

Installation, Operation and Maintenance Manual

UFO 

37

uk.ufosecurity.com

DOUBLE PULSE FUNCTION

If the room in which the fogger is positioned is subject to sources of reflection, 

heat or high brightness, you can contact service and have the double-pulse 

function activated. Its operation involves 2 detection pulses from the sensors. 

The second pulse is only triggered within a preset time from when the first pulse 

was triggered.

The steps the machine performs in this function are as follows:

• 

On the first pulse the alarm siren is triggered and the GSM module will call 

the registered mobile phone numbers, also sending an SMS;

• 

On the second impulse the fog machine starts firing.

CLOUD DIALER

The 

cloud dialer 

can be managed from the Ufo Security app. For its use, see the 

section ‘Configuring alarm messages’. With it you can set up customised alarm 

messages, which will be played in voice calls and written in SMS to specific 

numbers.

The dialer can make a maximum of 5 calls per 24 hours. Once this limit has 

been exceeded, an SMS with the customised message in text form will be sent 

for subsequent alarms.

The number of the dialer is 

+39 0423 173 0004

. It is advisable to save this num-

ber in the address book.

If a call from the dialer is missed or rejected, no further attempts will be made.

attempts.

If the fogger disconnects from the cloud, an SMS message will be sent to the 

registered numbers saying “Device x has disconnected”, where x is the name of 

the device. 

TELEPHONE DIALER (UFO XTREME)

The telephone dialer is only included in the UFO Xtreme, and allows you to make 

voice calls and send SMS messages to preset numbers in the event of theft. 

For it to work, you need to insert a full-size SIM card with PIN, voicemail and call 

notification deactivated.

If the SIM has just been purchased activate it beforehand (usually by making an 

outgoing call) and check its expiry date, credit and any service limits.

Содержание Basic L

Страница 1: ...OLUTION Installation Operation and Maintenance Manual FOG ANTI THEFT SYSTEM Ufo Security LTD Address Chase Green House 42 Chase Side Enfield EN2 6NF London Tel 08082380020 E mail uk ufosecurity com uk...

Страница 2: ......

Страница 3: ...TOGRAMS WARRANTY GENERAL SAFETY RULES WARNING SECURITY RULES DESCRIPTION MAINTENANCE DISPOSAL DECOMMISSIONING WARNINGS PANORAMICS SITING MOVING UFO CONFIGUARATION SACK CHANGING MACHINE STATES SENSORS...

Страница 4: ...01 Declaration of conformity p 5 Manufacter data p 7 Presentation of the Manual p 8...

Страница 5: ...by Eng Renato Carraro Sign Place Serial number view product label VAT Number 13446957 Directive 2014 53 UE called as Radio Equipment Directive RED Directive 2014 35 UE called as Low Voltage Directive...

Страница 6: ...ance Manual UFO uk ufosecurity com 6 NOTE BEFORE USING THE DI DISPOSITIVE IN ANY FORM CHECK FOR THE PRESENCE OF THE DECLARATION OF CONFORMITY NOTE IF THE DEVICE IS GIVEN TO A THIRD PARTY ALL DOCUMENTA...

Страница 7: ...82380020 VAT CODE GB 397 7719 23 E mail uk ufosecurity com Company HQ Chase Green House 42 Chase Side Enfield EN2 6NF London CEM whiteufo legalmail it Website uk ufosecurity com AUTHORISED ASSISTANCE...

Страница 8: ...F THE DEVICE PLEASE READ THIS MANUAL CAREFULLY BEFORE PERFORMING ANY OPERATION MANUAL PRESENTATION This manual contains proprietary information and may not be even partially provided to third parties...

Страница 9: ...THE FOLLOWING ATTENTION INDICATIONS INDICATE THOSE PROCEDURES WHO SE TOTAL OR PARTIAL NONCOMPLIANCE MAY CAUSE DAMAGE TO THE DEVICE ITS COMPONENTS AND MAY EXPOSE PEOPLE TO DANGER DANGER HAZARD INDICATI...

Страница 10: ...02 Warranty p 11 General Safety Rules p 12 Technic information p 14 Planned and unplanned use p 17 Left risks p 17...

Страница 11: ...ir or replacement of the product are always borne by the purchaser Only the original purchaser who has complied with the normal maintenance instructions in the manual may benefit from this guarantee O...

Страница 12: ...ment Detailed description of the problem Serial Number ______________________ Notice If you consider it necessary to use the guarantee please provide the following informa tion NOTE FAILURE TO COMPLY...

Страница 13: ...ted therefore that in all cases where the regulations of the documentation conflict with or are reductive to the regulations of the country in which the anti theft system is used the regulations of th...

Страница 14: ...T MUST NOT OR CANNOT BE PERFORMED CONSIDER THAT ALL OPERATIONS OTHER THAN NORMAL USE THAT ARE NOT EXPLICITLY DESCRIBED IN THE MANUAL SUPPLIED WITH THE DEVICE ARE TO BE REGARDED AS NOT FEASIBLE Overall...

Страница 15: ...ions mm Power supply V 440 x 276 x 212 220 230 Ac Recharge weight ml Consumption W Speed of diffusion Electrical safety class Radio Trasmission 500 30 60 29m sec Class I earthing Wireless Weight kg Fr...

Страница 16: ...ions mm Power supply V 444 x 363 x 228 220 230 Ac Recharge weight ml Consumption W Speed of diffusion Electrical safety class Radio Trasmission 500 30 80 29m sec Class I earthing Wireless Weight kg Fr...

Страница 17: ...s warehouses homes studios and all enclosed spaces NOT INTENDED USE No use other than those described in the DESCRIPTION and INTENDED USE section is envisaged It is also absolutely forbidden The use o...

Страница 18: ...data for managing the anti theft system Should the user have any doubts about the secrecy of the alarm system s access and management data he she can change them by following the instructions given i...

Страница 19: ......

Страница 20: ...ion Sack Change Machine Status Sensors Total and partial weapon LED Description Multi Function Button Multi Device Network Dual pulse function Dialer UfoSecurity App Troubleshooting p 21 p 22 p 24 p 2...

Страница 21: ...all work where there is a risk of a potentially dangerous part falling Protective goggles these are necessary in all work where there is a risk that an object and or material may be projected into an...

Страница 22: ...s an electrical and electronic device for use as an anti theft system in shops commercial premises offices warehouses homes studios and all enclosed spaces It protects the premises from theft by firin...

Страница 23: ...board with microcontroller A mouthpiece for the bag containing the liquid A boiler to vaporise the liquid A pump to carry the liquid from the bag to the boiler A solenoid valve to alternate the flow...

Страница 24: ...weather The fog device must be positioned at a height of between 1 80 metres and 2 20 metres The Pir sensor has a detection angle of 90 degrees so the fog generator should not be placed in a corner wi...

Страница 25: ...For the procedure from the app please refer to the Ufo Security App section page 36 Manual Procedure To manually configure network settings Web Server mode must be enabled on the device It is automati...

Страница 26: ...iFi settings Point 3 Point 4 Point 5 SACK CHANGE PROCEDURE There are 2 ways to change the bag Start the procedure from the multifunction button Start the procedure from the Ufo Security app for this p...

Страница 27: ...fog if the boiler is at temperature If the boiler drops below a certain temperature threshold the machine switches to the cleaning cycle The firing can be interrupted by disarming the machine In the...

Страница 28: ...NUTES Anti Theft Function Anti Theft Function It can be activated in immediate emergency situations by pressing the anti robbery button on the remote control see section on sensors for more info on ac...

Страница 29: ...D indicates infrared detections Pir sensor sensitivity configuration 1 Open the plastic casing by inserting a thin object such as a screwdriver into the hole at the bottom of the sensor 2 BATTERY PLAC...

Страница 30: ...range should be adjusted to the minimum necessary as the uW passes through walls and an excessive range does not increase performance in the protected area The illumination of the red LED indicates i...

Страница 31: ...upper part of the body 3 Remove the green card by turning the remote control upside down The CR2032 battery is located at the back 4 Remove the battery from the tab then insert the new one taking car...

Страница 32: ...rocedure for attaching the clamp to the sensor 1 Lean the clamp against the wall and drill two holes with a drill machine at the two side holes of the bracket 2 Insert the rawlplugs and then the 2 scr...

Страница 33: ...o it For example if I have a two room apartment with 1 UFO and I want to be able to decide when to trigger the sensors in room 2 I can set the sensor zone in room 1 as Total and the sensor zone in roo...

Страница 34: ...ing Steady Blue UFO Armed Steady red Bag depletion Flashing Red Reserve Bag Flashing White Error see error codes Red 3 fast flashes Confirmation of change in configuration of sensors associated with t...

Страница 35: ...er does not come up to temperature 9 Command refused An unmanageable command has been given 10 Firing not started Errors can be reset either from the app or with the multifunction button MULTI FUCTION...

Страница 36: ...ault For example if you associate 3 fog machines UFO1 UFO2 and UFO3 to the Test network and then set UFO2 as Master in this network you will have 1 Master UFO2 and 2 Slaves UFO1 and UFO3 If you have a...

Страница 37: ...ages which will be played in voice calls and written in SMS to specific numbers The dialer can make a maximum of 5 calls per 24 hours Once this limit has been exceeded an SMS with the customised messa...

Страница 38: ...s a Vodafone Micro SIM with a maximum life of 2 years The customer will be notified of the mobile phone number before the device is shipped so that it can be saved in the address book To insert the SI...

Страница 39: ...the Play Store on Android smartphones It includes the following features Management of all existing fog machines Configuration of new fog generators Sending arming disarming anti robbery liquid reset...

Страница 40: ...nfigure a new device Photo 1 2 If the Fogger s Wi Fi settings have not been previously configured a wizard will open Follow this procedure Photo 2 3 Once the device has been configured to the network...

Страница 41: ...device from the app Ufo activity to view the logs activity history of the device Manage Accessories to access the configuration section of the Multi Device Network mode and sensors Time Scheduler to a...

Страница 42: ...the accessories connected to the UFO will be listed To associate a new accessory sensor 1 Press on the icon on the right or press on Add an accessory in case there is no accessory configured 2 In the...

Страница 43: ...s active when On is green By pressing on the 3 dots on the right for each sensor you can the details change the sensor zone or delete it If the sensor details are not loaded correctly try sending a co...

Страница 44: ...ensor operation it is recommended to maintain a connection quality between 0 and 70 To change the sensor zone 1 Press on the 3 dots to the right Edit zone 2 Press on the top right where the current se...

Страница 45: ...on Create a new network 4 Enter the name of the network and press on Create Network 5 A section will appear with the network name and an option to set the fogger as Master or Slave It is set as Slave...

Страница 46: ...will be listed on this screen Press on Record a new message or on the icon on the top right 3 Enter the phone number to which the call will be made and the personalised message that will be played ba...

Страница 47: ...Installation Operation and Maintenance Manual UFO 47 uk ufosecurity com PIN ILLUSTRATION...

Страница 48: ...hat the command was sent by a sensor check that this sensor has a charged battery see changing the battery in the sensors section If it is a Pir sensor check that the sensitivity is set correctly If t...

Страница 49: ......

Страница 50: ...04 Maintenance p 50 Decommissioning p 52...

Страница 51: ...where these operations are carried out must be observed During physical maintenance operations on the alarm system the use of personal protective equipment PPE must be provided such as Clothing compl...

Страница 52: ...of the anti theft system Updates Always keep the Ufo connected to the Internet connection to allow the device s management firmware to be updated to avoid unpleasant bugs and malfunctions Extraordinar...

Страница 53: ...ommissioning and subsequent disposal Disposal The possibility of reusing certain parts of the device is subject to the full responsibility of the user NOTE THE MANUFACTURER ASSUMES NO LIABILITY FOR PE...

Страница 54: ...Installation Operation and Maintenance Manual UFO uk ufosecurity com 54...

Страница 55: ...urity LTD Chase Green House 42 Chase Side Enfield EN2 6NF London Big Yellow Storage Staples Corner Business Park 1 1000 N Circular Rd London NW2 7JP E mail uk ufosecurity com uk ufosecurity com 0808 2...

Отзывы: