Version 1
32
UP2000 Specifications
Construction
Hand-held metered pistol type made with aluminum and ABS plastic
Circuitry
Solid State heterodyne receiver with temperature compentsation
Frequency
Response
Ultraschallfrequenzen zwischen 20kHz und 100 kHz, stufenlos einstellbar
Frequenzen werden auf 50 kHz bis 3 kHz Audio moduliert Frequency Detect
ultrasonic frequencies between 20kHz and 100 kHz, continuously variable
Frequencies are converted to 50 kHz to 3 kHz audio
Probes
Scanning Module
patented Trisonic plug-in type consisting of a phased array of
multiple transducers for airborne ultrasound. This probe is shielded against RF
interference.
Rubber Focusing Probe
(flexible) slips over scanning module to concentrate
conical directivity and to shield reception of stray ultrasound. Also fits over
Stethoscope Module to shield against high ambient ultrasound while unit is at
maximum sensitivity.
Stethoscope Module
plug-in type, insulated probe with RF shielding; 11.4cm
long stainless steel probe tip, conically shaped for uniform surface contact.
Stethoscope Extension Kit: 3-piece, segmented metal rods to increase
stethoscope contact range for 50.8 cm and 76.2 cm.
Transmitter
Patented warble tone transmission
Headset
Noise isolating type: Double headset wired monophonic Impedance 16 ohms.
Over 23 dB of noise attenuation. Meets or exceeds ANSI specifications and
OSHA standards. For hard hat use.
Indicators
Ballistic ouput meter; linear calibration scale of 0-100 for logging relative
measurements. Meter is accurate 1% throughout entire scale. Low level Battery
LED indicator for main housing internal power supply.
Battery
Self containd NIMH rechargeable.
RECHARGING SYSTEM: Standard 110V. Also available in 220V.
Features
Frequency Tuning Adjustment Dial:
20-100kHz with (fixed band) position for
ultra-narrow frequency response.
Bi-Modal Meter Switch
for logarithmic and linear meter scale adjustments.
Optional Auxillary Mode
selection for chart recorder output: 0-50mV.
Sensitivity Control
Precision 10-turn adjustment dial with numerically calibrated
sensitivity increments for finite gain adjustment
Spring loaded trigger switch
Overall Size
Complete kit in Zero Halliburton aluminum carrying case:
47x37x17 cm
Pistol unit: 0.9kg
Complete carrying case: 6.4kg
Sensitivity
Detects 0.1 mm diameter leak @ 0.3 bar at a distance of 15 m.
Threshold*
1 x 10
–2
std. cc/sec bis 1 x 10
–3
std. cc/sec
Waranty
1-Year parts/labor standard,
5 years with completed warranty registration card.
Display Modes
Logarithmic and Linear
*depends on leak configuration
** specify Ex rating if needed at time or order