Version 1
10
Headset
This heavy duty headset is designed to block out intense sounds often found in industrial environments so
that the user may easily hear the sounds received by the ULTRAPROBE. To use, simply plug the headset
cord into the headset Jack on the metered pistol housing, and place the headphones over your ears. If a
hard hat is to be worn, it is recommended to use
UE Systems' model UE-DHC-2HH Hard Hat Headphones which are specifically designed for hard hat use.
For those situations in which it is not possible or difficult to wear the standard headphones described
above, UE Systems has two options available:
1. The DHC 1991 Earpiece which loops around the ear,
2. The SA-2000 Speaker Amplifier which is a loud speaker that is compatible with the Ultraprobe
headphone output jack.
WTG - 1 Warble Tone Generator (Standard)
The WTG-1 Tone Generator is an ultrasonic transmitter designed to flood an area with ultrasound. It is
used for a special type of leak test. When placed inside an empty container or on one side of a test item,
it will flood that area with an intense ultrasound that will not penetrate any solid but will flow through any
existing fault or void. By scanning with the Trisonic Scanning Module, empty containers such as pipes,
tanks, where the "warble" ultrasound penetrates. As an example, if the item to be tested is the seal
around a window, place the Warble Tone Generator on one side of the window, close it and proceed to
scan on the opposite side. To test the condition of the Warble Tone Generator battery, set to the LOW
INTENSITY position and listen to the sound through the Ultraprobe in the FIXED BAND mode. A smooth
continuous warbling sound should be heard. If a "beeping" is heard instead, then a full recharge of the
Warble Tone Generator is indicated.
To use the WARBLE TONE GENERATOR:
1. Turn Tone Generator on by selecting either "LOW" for a low amplitude signal (usually
recommended for small containers) or "HIGH" for high amplitude. In high, the Warble Tone
Generator will cover up to 113m
³
(4,000 cubic feet) of unobstructed space. When the Tone
Generator is on, a red light (located below the recharge Jack in the front) flickers.
2. Place the Warble Tone Generator within the test item/container and seal or close it. Then scan the
suspect areas with the Trisonic Scanning Module in the Ultraprobe and listen for where the
"warble" ultrasound penetrates. As an example, if the item to be tested is the seal around a
window, place the Warble Tone Generator on one side of the window, close it and proceed to scan
on the opposite side.
To charge the Warble Tone Generator
Follow directions in 1.1-1 RECHARGE JACK
wtg1 warble tone generator (optional
)
UE-WTG-2SP Warble Pipe Tone Generator