6 | SWIFT K33A ALL IN ONE FUSION SPLICER
americanilsintech.com | 7
K33A USER MANUAL
FOR YOUR SAFETY
The Swift K33A All in One core Align fusion splicer is designed for use both outdoors and
indoors providing thermal stripping, cleaning, cleaving, fusion splicing and heat shrinking
all with one easy to use tool. We strongly recommend users to read this manual carefully
prior to operating the Swift K33A in order to prevent any accident or breakdown due to
improper handling. Misuse of this device may cause injury or damage not covered by the
warranty. This user manual provides all the necessary information to ensure splicing safely.
KEEP THIS USER MANUAL WITH THE DEVICE AT ALL TIMES.
UCLSWIFT Co., Ltd is not liable for any personal injury, any physical loss and damage to the
device caused by inappropriate use or unauthorized modifi cation of the equipment.
PRODUCT SAFETY WARNINGS
Please, turn off the Swift K33A and disconnect the AC power cord from the AC adapter
inlet or the wall socket immediately and contact UCLSWIFT Co., Ltd.
If any of following incidents occurs while operating:
— Fumes, odor, noise or overheating.
— Liquid or foreign substances fall into the device.
— The splicer is dropped or damaged.
Only use the supplied power cord with the Swift K33A. Using an improper AC power cord
may cause fi re, electric shock or personal injury.
DO NOT
touch the electrodes when the Swift K33A is powered on. The high voltage and
temperature generated by electrodes may cause electric shock or injury.
When connecting the supplied AC power cord to the battery check to ensure no dust or
foreign substance is on the AC plugs before connecting it. Unsafe connection may cause
fumes, fi re or damage to the Swift K33A and result in serious personal injury or death.
Apply correct voltage. The correct input AC power to the adapter is AC 100- 240V and
50-60Hz. Abnormally high AC output voltage or irregular frequencies generated by AC
generators can cause damage to the battery and/or the K33A. Please measure the AC
output voltage with a circuit tester. Abnormal high voltage and frequencies may result
in serious electric shock, injury, death or damage to the equipment, it is important that
regularly check the generator before use.
DO NOT
excessively pull, amend, misuse or apply
heat to the AC power cable. Using a damaged power cable may result in fi re or personal
injury. Connect 3-prong AC power cord.
DO NOT
use 2-prong, cable and plug.
DO NOT
touch the AC plugs, AC power cable or the Swift K33A with wet hands. It may
cause an electric shock.
DO NOT
disassemble the AC adapter, battery or the Swift K33A. Any modifi cation may
cause fi re, electric shock or personal injury and void the warranty.
When using the battery, follow instructions below:
— Using battery other than in the package or provided by UCLSWIFT Co., Ltd may
cause fumes, damage to the device, burn, serious injury or even death.
—
DO NOT
throw the battery into fi re or an incinerator.
—
DO NOT
charge the battery near a fl ame.
—
DO NOT
apply excessive shock to the battery.
— If the battery is not fully charged or the green LED is not turned on in about two
hours, stop charging immediately and contact UCLSWIFT Co., Ltd.
DO NOT
put
anything on the AC adapter while charging.
Use the supplied AC adapter (F1-1) at all times.
DO NOT
use other type of AC power
cord and the battery. Excessive electric current may cause damage to the machine and
personal injury.
D
O NOT
run the Swift K33A near fl ammable liquid or explosive gas storage. The electric arc
of the Swift K33A may cause fi re or explosion.
DO NOT
clean the Swift K33A using compressed air or gas.
Please check the shoulder belt before transporting. Transporting the case with a damaged
shoulder belt may cause the damage of the Swift K33A and possibly personal injury.
Make sure to wear protective glasses while splicing with the K33A at all times. If the fi ber
fragments come into contact with the eyes or skin, it can be extremely dangerous.
DO NOT
operate the Swift K33A at a high temperature or near heat, otherwise personal
injury or damage to the device may occur.
|
EXTREMELY HOT
|
DO NOT SPRAY FREON GAS
|
CAUTION HIGH VOLTAGE