Ubiquiti TS-5-POE ToughSwitchPoE Скачать руководство пользователя страница 27

24

Chapter 6: Ports Tab 

TOUGHSwitch

 PoE User Guide

 Ubiquiti Networks, Inc.

Revert Changes 

To cancel your changes, click 

Revert 

Changes

.

Test Changes 

To try the changes without saving them, 

click 

Test Changes

. To keep the changes, click 

Apply

. If 

you do not click 

Apply

 within 180 seconds (the countdown 

is displayed), the device times out and resumes its earlier 
configuration. 

Save Changes 

To immediately save your changes, click 

Save Changes

.

Clone Settings for All Ports 

After you have made 

changes for the selected port, click this button to apply 
the same changes to all ports. Then click 

Save Changes

.

WARNING:

 The 

PoE

 setting is also cloned. Ensure that 

the same 

PoE

 setting suits all ports before you clone 

the settings of the selected port.

Basic Settings for Port

Name 

Enter a name for the port.

Port Status 

To use this port, check the box.

Note:

 If you disable a port, its 

PoE

 functionality 

remains.

PoE 

PoE is disabled by default on all ports. To output PoE 

to the connected device, select 

24V

 or 

48V

 (

48V

 available 

only on the TOUGHSwitch PoE PRO). To disable PoE, 

select Off

.

Note:

 Before enabling PoE, check the specifications 

of your airMAX, UniFi, legacy, or third-party devices 
to ensure they support passive PoE and require the 
available amount of voltage. The TOUGHSwitch PoE 
offers 24V passive PoE, and the TOUGHSwitch PoE 
PRO offers 24V or 48V passive PoE.

Link Speed, Mbps 

By default, 

Auto

 is enabled. The 

TOUGHSwitch automatically negotiates transmission 
parameters, such as speed and duplex, with its 
counterpart. In this process, the networked devices 
first share their capabilities and then choose the fastest 
transmission mode they both support. 

Note:

 

Auto

 applies only to speed and duplex, not 

POE.

To manually specify the maximum transmission link speed 
and duplex mode, select 

100Mbps-Full

100Mbps-Half

10Mbps-Full

, or 

10Mbps-Half. 

Full-duplex mode allows 

communication in both directions simultaneously. 
Half-duplex mode allows communication in one direction 
at a time, alternating between transmission and reception.
To achieve full performance with extra-long Ethernet 
cables, ensure that you use CAT6-qualified cables and 
interconnects.

Flow Control 

Enabled by default. 

Flow Control

 allows 

the port to manage data rates in case the sending and 
receiving devices use different data transmission rates. 

Ping Watchdog for Port

Ping Watchdog

 is only for PoE-enabled ports. It configures 

the device to continuously ping a user-defined IP address 
(it can be the Internet gateway, for example). If it is 
unable to ping under the user-defined constraints, then 
the device will automatically turn off PoE on the port, 
and then turn it back on. This option creates a kind of 
“fail-proof” mechanism.

Ping Watchdog

 is dedicated to continuous monitoring of 

the specific connection to the remote host using the 

Ping

 

tool. The 

Ping

 tool works by sending ICMP echo request 

packets to the target host and listening for ICMP echo 
response replies. If the specified number of replies is not 
received, the tool reboots the device.

Port Ping Watchdog 

Enables use of Ping Watchdog.

• 

IP Address To Ping 

Specify the IP address of the target 

host to be monitored by 

Ping Watchdog

.

• 

Ping Interval 

Specify the time interval (in seconds) 

between the ICMP echo requests that are sent by 

Ping 

Watchdog

. The default value is 

15

 seconds.

• 

Startup Delay 

Specify the initial time delay (in seconds) 

until the first ICMP echo requests are sent by 

Ping 

Watchdog

. The default value is 

300 

seconds.

The 

Startup Delay

 value should be at least 60 seconds 

as the network interface and wireless connection 
initialization takes a considerable amount of time if the 
device is rebooted.

• 

Failure Count 

Specify the number of ICMP echo 

response replies. If the specified number of ICMP echo 
response packets is not received continuously, 

Ping 

Watchdog

 will reboot the device. The default value is 

3

.

• 

Cut Power for 

Specify the number of seconds this port 

should pause PoE (if applicable). The default value is 

seconds.

WARNING:

 Cutting power during a firmware 

upgrade can damage your device. Ensure that you 
specify a safe 

Ping Interval

.

Содержание TS-5-POE ToughSwitchPoE

Страница 1: ...Power over Ethernet Managed Switches Models TS 5 POE TS 8 PRO TS 16 CARRIER...

Страница 2: ...Switch PoE CARRIER 9 Chapter 3 Navigation 11 Accessing the Configuration Interface 11 Configuring the TOUGHSwitch PoE CARRIER 12 Product Verification 12 Interface Tabs 12 Chapter 4 Status Tab 13 Statu...

Страница 3: ...rt Log 28 System Log 29 Chapter 9 Tools 30 MAC Forwarding Table 30 Ping 31 Traceroute 31 Discovery 31 Appendix A Specifications 32 Appendix B Safety Notices 34 Electrical Safety Information 34 Appendi...

Страница 4: ...uring 24V PoE TOUGHSwitch PoE PRO TS 8 PRO 8 port managed switch featuring 24V 48V PoE TOUGHSwitch PoE CARRIER TS 16 CARRIER Two TOUGHSwitch PoE PROs mounted in a rack The TOUGHSwitch is a managed swi...

Страница 5: ...to factory defaults press and hold the Reset button for more than 10 seconds while the unit is already powered on Front Panel LEDs Power Link PoE Speed Link Act LED State Status Management Power Link...

Страница 6: ...Reset To reset to factory defaults press and hold the Reset button for more than 10 seconds while the unit is already powered on Front Panel LEDs Power Link PoE Speed Link Act LED State Status Managem...

Страница 7: ...s on the top and sides of the TOUGHSwitch Front Panel Ports TOUGHSwitch A TOUGHSwitch B Management Ports 1 8 Reset USB Management Ports 1 8 Reset USB Interface Description Management 10 100 Mbps port...

Страница 8: ...ndicates a 10 100 Mbps connection If the link terminates the LED turns off until a link is re established If the unit reboots the LED will again indicate power until a link is established 1 8 PoE Off...

Страница 9: ...end that you protect your outdoor networks from the most brutal environments and devastating ESD attacks with industrial grade shielded Ethernet cable from Ubiquiti Networks For more details visit www...

Страница 10: ...Power Cord to a power outlet Connecting Ethernet 1 Connect an Ethernet cable from the Ethernet port of your computer to the Management port of the TOUGHSwitch 2 Connect Ethernet cables from the Ether...

Страница 11: ...hielded Ethernet cable from Ubiquiti Networks For more details visit www ubnt com toughcable Note Although the cabling can be located outdoors the TOUGHSwitch itself should be housed inside a protecti...

Страница 12: ...Ubiquiti Networks For more details visit www ubnt com toughcable Note Although the cabling can be located outdoors the TOUGHSwitch PoE CARRIER itself should be housed inside a protective enclosure Har...

Страница 13: ...After you have finished the installation proceed to Configuring the TOUGHSwitch PoE CARRIER on page 12 Uplink Options The TOUGHSwitch PoE CARRIER functions as two separate switches All data ports are...

Страница 14: ...the following steps 1 Ensure that your computer or other host machine is connected to the Management port on the TOUGHSwitch Note By default you can configure the TOUGHSwitch via any port however we r...

Страница 15: ...her a product is genuine or counterfeit For a genuine TOUGHSwitch the Configuration Interface will display a Genuine Product logo in the lower left corner of the screen For any product that is not an...

Страница 16: ...a summary of the link status information current values of the basic configuration settings network settings and information and traffic statistics The TOUGHSwitch image displays the active LEDs and...

Страница 17: ...ctivity status of the link connection Link Status Displays the speed and duplex mode of the port If the port is inactive Down is displayed PoE Displays the status and voltage of the PoE feature 24V is...

Страница 18: ...Distribution are displayed Total Throughput displays the current data traffic on the TOUGHSwitch in both graphical and numerical form The chart scale and throughput dimension bps kbps Mbps change dyna...

Страница 19: ...hart scale and packet rate dimension change dynamically depending on the mean packet rate value The statistics are updated automatically Throughput Throughput displays the current data traffic on the...

Страница 20: ...e Update Management Network Settings Basic Settings Management Connection Settings Services Spanning Tree Protocol Jumbo Frames Device Discovery System Account Device Maintenance and Configuration Man...

Страница 21: ...t disconnect the TOUGHSwitch from the power supply during the firmware update process as these actions will damage the TOUGHSwitch Management Network Settings The Management Network Settings configure...

Страница 22: ...nt reports it to authorized management stations The Device Name will be used in popular router operating systems registration screens and discovery tools Time Zone Specify the time zone in relation to...

Страница 23: ...ce monitoring using SNMP Communicates with SNMP management applications for network provisioning Allows network administrators to monitor network performance and troubleshoot network problems For the...

Страница 24: ...there should be a single active path between two networking devices in an Ethernet network Spanning Tree Protocol STP provides redundant paths and prevents network loops that can create excessive traf...

Страница 25: ...nerated at their request Configuration Management This section manages device configuration routines and the option to reset the device to factory default settings The device configuration is stored i...

Страница 26: ...ngs click the port on the image Then the port is highlighted in blue Total Throughput for TX and RX are also displayed Place your mouse over a port to view its PoE status Speed setting duplex mode and...

Страница 27: ...ation in one direction at a time alternating between transmission and reception To achieve full performance with extra long Ethernet cables ensure that you use CAT6 qualified cables and interconnects...

Страница 28: ...iority The lower the value the better STP uses the Priority as a tiebreaker If the Path Cost of multiple ports are the same then STP chooses the port with the highest Priority lowest value as the acti...

Страница 29: ...cs for TX and RX throughput Revert Changes To cancel your changes click Revert Changes Test Changes To try the changes without saving them click Test Changes To keep the changes click Apply If you do...

Страница 30: ...sign its membership status as a tagged or untagged member of this VLAN You can also exclude a port from this VLAN T tag The port belongs to this VLAN and VLAN tags are included on outgoing frames Clic...

Страница 31: ...the Alert Log lists all alerts By default alert logging is disabled Port To display entries for all ports select All To display entries for a specific port select the port number from the drop down l...

Страница 32: ...g is enabled on the Device tab see System Log on page 21 the System Log lists all system events By default system logging is disabled When system logging is enabled there are two buttons available Cle...

Страница 33: ...plays the MAC addresses of the hardware devices using the TOUGHSwitch MAC Table Port All is the default To view the MAC addresses of the hardware devices using a specific port select the port from the...

Страница 34: ...ch to a specified outgoing IP address Use this tool to find the route taken by ICMP packets across the network to the destination host Destination Host Enter the IP address of the destination host Res...

Страница 35: ...D Rating 24 kV Air 24 kV Contact PoE Method Passive Button Reset USB Port 2 0 Type A Reserved for Future Use Processor MIPS 24K 400 MHz System Memory 64 MB Code Storage 8 MB Certifications CE FCC IC W...

Страница 36: ...4K 400 MHz System Memory 64 MB Code Storage 8 MB Certifications CE FCC IC Operating Temperature 25 to 55 C Operating Humidity 90 Non Condensing PoE Configurable Per Port Management N A Data Ports Off...

Страница 37: ...ts inside this equipment Service should be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended f...

Страница 38: ...process of UBIQUITI NETWORKS Products returned without an RMA number will not be processed and will be returned freight collect or subject to disposal Information on the RMA process and obtaining an R...

Страница 39: ...tates and provinces do not allow the exclusion or limitation of liability for incidental or consequential damages so the above limitation may not apply to you EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW...

Страница 40: ...is product represents the product is in compliance with all directives that are applicable to it RoHS WEEE Compliance Statement English European Directive 2002 96 EC requires that the equipment bearin...

Страница 41: ...votre responsabilit de jeter ce mat riel ainsi que tout autre mat riel lectrique ou lectronique par les moyens de collecte indiqu s par le gouvernement et les pouvoirs publics des collectivit s terri...

Страница 42: ...inie 1999 5 EG Wien Greek UBIQUITI NETWORKS UBIQUITI NETWORKS device 1995 5 Magyar Hungarian Alul rott UBIQUITI NETWORKS nyilatkozom hogy a UBIQUITI NETWORKS device megfelel a vonatkoz alapvet k vetel...

Страница 43: ...bility or field issues as quickly as possible We strive to respond to support inquiries within a 24 hour period Online Resources Support support ubnt com Community community ubnt com Downloads downloa...

Отзывы: