4
Dear customer,
We would like to thank you for purchasing this product, one of the high-quality Ubbink BioBalance pond fi lter series.
This operating instruction contains important information that is useful for installation, start-up and care of your BioPressure pressure fi lter. Please read the operating instruction
carefully before installing the fi lter.
The following components are contained in the scope of delivery of the BioPressure:
1 Pressure fi lter container 10 l (BioPressure 3000) / 18 l (BioPressure 7000)
1 Pressure fi lter cover with inlet and outlet connections, ball valve for dirt drainage
1 UV-C-Device 5 W (BioPressure 3000) / 9 W (BioPressure 7000), integrated
1 UV-C-Lamp PL-S 5 W (BioPressure 3000) / PL-S 9 W (BioPressure 7000)
1 Locking bracket, two parts with screws
1 Rubber sealing ring
1 Tube of conservation and sealing medium
1 Level fi lter mat set
1 Protective cover for the pressure fi lter, removable
1 Operating instructions
Technical data
BioPressure 3000
BioPressure 7000
Article No.
1355400 (UK-Version: 1355401)
1355402 (UK-Version: 1355403)
Filter contents
10 Litres
18 Litres
Filter medium
Foamed material – Level fi lter mat
Foamed material – Level fi lter mat
UV-C lamp
PL-S 5 Watt
PL-S 9 Watt
Operation period UV-C lamp
approx. 5,000 Hours
approx. 5,000 Hours
UV-C (%) after 5,000 Hours
approx. 85%
approx. 85%
Article no. of spare lamp
1355109
1355110
Article no of quartz glass
1358520
1358521
Max. contents of the pond
3.000 Litres
7.000 Litres
Max. fl ow rate (Qmax)
5.000 L/h
5.000 L/h
Max. delivery height (Hmax.)
4.9 m (0.49 bar)
4.9 m (0.49 bar)
Hose connections
25 mm
25 mm
Recommended guide value for the pump
Pond volume
Pump capacity
BioPressure 3000
Pump capacity
BioPressure 7000
Without fi sh
With fi sh
1,000 Litres
500 Litres
250-500 L/h
2,000 Litres
1,000 Litres
500-1000 L/h
3,000 Litres
1,500 Litres
750-1500 L/h
4,000 Litres
2,000 Litres
1,000-2,000 L/h
5,000 Litres
2,500 Litres
1,250-2500 L/h
6,000 Litres
3,000 Litres
1,500-3,000 L/h
7,000 Litres
3,500 Litres
1,750-3,500 L/h
Safety information
WARNING: UV-C rays are dangerous for eyes and skin. The UV-C ray emitter must not be operated, if it has been taken out of the device!
CAREFUL: This device contains a UV-C ray emitter! Unintended usage of the device or damage to the housing can lead to emission of dangerous UV-C radiation. UV-C radiation can
damage eyes and skin also in small doses.
- The device must be separated from the mains before every intervention (Installation, maintenance, etc.)!
- The power supply must meet the product specifi cations. Do not connect the device, if the power supply does not meet the specifi ed regulations! Further information can be
obtained from your local, approved electrician.
- The power supply of the device must be secured via a fault current protection switch (FI or RCD) with a rated fault current of maximum 30 mA.
- Under no circumstances must the device be operated under water and must be installed beside the pond in such a way that fl ooding is excluded.
- The device must be installed more than 2 m away from the pond or water basin and the mains connection more than 3.5 m.
- It is not permitted to open the device or accompanying parts, if not explicitly pointed out in this operating instruction. This goes also for technical modifi cations to the device.
- The device is fi tted with an integrated protective switch, which interrupts the power supply automatically if the device is opened.
- The mains plug and all connection locations must always be kept dry. The connecting cable of the device must be routed protected to avoid possible damages.
- The device must only be operated if the installation of all components and hose connections is completed.
- Ensure that the device is switched off , if no water fl ows through the device.
- The device must only be operated at a water temperature from +5 °C to +35 °C.
- Devices with obvious damages must not be operated!
- It is not possible to replace the power cable. If the cable gets damaged, the UV-C device must be correctly disposed.
- Never look directly into the switched on UV-C ray emitter, but always check its function through the transparent hose connection with the device closed.
- The device is not suitable for usage by persons (Including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless supervised by
a person responsible for their safety or if they have been instructed in the usage of the device. Children must be supervised to ensure that they are not playing with the device.
1
Operating instructions Ubbink BioPressure 3000/7000
Manual biopressure 12.indd 4
06-12-12 10:05
Содержание BioPressure 7000
Страница 1: ...BioPressure Manual biopressure 12 indd 1 06 12 12 10 05...
Страница 2: ...2 180 180 180 180 Manual biopressure 12 indd 2 06 12 12 10 05...
Страница 3: ...3 B A D C Manual biopressure 12 indd 3 06 12 12 10 05...
Страница 63: ...63 Manual biopressure 12 indd 63 06 12 12 10 06...
Страница 64: ...Manual biopressure 12 indd 64 06 12 12 10 06...