background image

QUICK START GUIDE

u-line.com

6

USER GUIDE

u-line.com

Water Hookup

Water Hookup

PREPARE PLUMBING

The water valve uses a standard 1/4” (6.35 mm) 
compression fitting. U-Line recommends using accessory 
water hook up kit – part # 80-54674-00. The kit includes 
a 10’ (3 m) braided flexible water supply line and a brass 
hose fitting.

Plumbing installation must observe all state 
and local codes. All water and drain connections 
MUST BE made by a licensed/qualified plumbing 
contractor. Failure to follow recommendations 
and instructions may result in damage and/or 
harm.

Water Supply Connection

When connecting the water supply, please note the 
following:

•  Before installing the unit and connecting to the cold 

water supply, review the local plumbing codes.

•  The water pressure should be between 20 and 120 psi 

(138 and 827 kPa).

•  Water has less than 400 mg/L (ppm) total dissolved 

solids and hardness level below 200 mg/L (ppm) — 
i.e., below 12 grains per gallon. Check by using TDS 
meter or consulting with local water company.

•  TDS and/or water hardness above these limits should 

be treated with a reverse osmosis system or other 
filtration system.

•  Softened water is not recommended as it may result in 

softer ice than desired.

•  The water line MUST have a shut-off valve in the 

supply line.

•  The water line should be looped into 2 coils. This 

will allow the unit to be removed for cleaning and 
servicing. Make certain that the tubing is not pinched 
or damaged during installation.

Do not use any plastic water supply line. The line 
is under pressure at all times. Plastic may crack 
or rupture with age and cause damage to your 
home.

Do not use tape or joint compound when 
attaching a braided flexible water supply line 
that includes a rubber gasket. The gasket 
provides an adequate seal – other materials 
could cause blockage of the valve.

Failure to follow recommendations and 
instructions may result in damage and/or harm, 
flooding or void the product warranty.

Use new hose set. Do not reuse old hose set.

Turn off water supply and disconnect electrical 

supply to unit prior to installation.

Use caution when handling back panel. The edges 

could be sharp.

CAUTION

!

CAUTION

!

CAUTION

!

USER GUIDE

u-line.com

Water Hookup

Water Hookup

PREPARE PLUMBING

The water valve uses a standard 1/4” (6.35 mm) 
compression fitting. U-Line recommends using accessory 
water hook up kit – part # 80-54674-00. The kit includes 
a 10’ (3 m) braided flexible water supply line and a brass 
hose fitting.

Plumbing installation must observe all state 
and local codes. All water and drain connections 
MUST BE made by a licensed/qualified plumbing 
contractor. Failure to follow recommendations 
and instructions may result in damage and/or 
harm.

Water Supply Connection

When connecting the water supply, please note the 
following:

•  Before installing the unit and connecting to the cold 

water supply, review the local plumbing codes.

•  The water pressure should be between 20 and 120 psi 

(138 and 827 kPa).

•  Water has less than 400 mg/L (ppm) total dissolved 

solids and hardness level below 200 mg/L (ppm) — 
i.e., below 12 grains per gallon. Check by using TDS 
meter or consulting with local water company.

•  TDS and/or water hardness above these limits should 

be treated with a reverse osmosis system or other 
filtration system.

•  Softened water is not recommended as it may result in 

softer ice than desired.

•  The water line MUST have a shut-off valve in the 

supply line.

•  The water line should be looped into 2 coils. This 

will allow the unit to be removed for cleaning and 
servicing. Make certain that the tubing is not pinched 
or damaged during installation.

Do not use any plastic water supply line. The line 
is under pressure at all times. Plastic may crack 
or rupture with age and cause damage to your 
home.

Do not use tape or joint compound when 
attaching a braided flexible water supply line 
that includes a rubber gasket. The gasket 
provides an adequate seal – other materials 
could cause blockage of the valve.

Failure to follow recommendations and 
instructions may result in damage and/or harm, 
flooding or void the product warranty.

Use new hose set. Do not reuse old hose set.

Turn off water supply and disconnect electrical 

supply to unit prior to installation.

Use caution when handling back panel. The edges 

could be sharp.

CAUTION

!

CAUTION

!

CAUTION

!

Water Hookup

Crescent Ice Makers

Содержание Outdoor Onb115

Страница 1: ...QUICK START GUIDE Outdoor Collection 30634 Rev_A 30634 Rev_E...

Страница 2: ...consin USA and select products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product...

Страница 3: ...rge when you register your product on u line com See complete warranty for details CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Water Hookup 6 Drain 12 Door Swing 13 Door Ad...

Страница 4: ...safety statement may result in minor or moderate personal injury property or equipment damage Your product may contain R600a Isobutane which is a flammable hydrocarbon To confirm check serial tag insi...

Страница 5: ...repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting...

Страница 6: ...installation Use caution when handling back panel The edges could be sharp CAUTION CAUTION CAUTION USER GUIDE u line com Water Hookup Water Hookup PREPARE PLUMBING The water valve uses a standard 1 4...

Страница 7: ...nlet 4 Break away filler feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn on water supply and ch...

Страница 8: ...installation Use caution when handling back panel The edges could be sharp CAUTION CAUTION CAUTION Water Hookup Clear Ice Machines USER GUIDE u line com Water Hookup Water Hookup PREPARE PLUMBING The...

Страница 9: ...mal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break awa...

Страница 10: ...stallation Use caution when handling back panel The edges could be sharp CAUTION CAUTION CAUTION Water Hookup Nugget Ice Machines USER GUIDE u line com Water Hookup Water Hookup PREPARE PLUMBING The w...

Страница 11: ...pply and disconnect electrical supply to product prior to attempting installation 2 Remove the back panel 3 Thread water line through back panel hole with bushing 4 Locate water valve inlet and connec...

Страница 12: ...an NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify...

Страница 13: ...clearance is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are...

Страница 14: ...t pinched on the hinge side of the door To align and adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on t...

Страница 15: ...bottom hinge Install two or three screws depending on model Replace nuts if used Prepare door for reinstallation 1 Remove gasket 2 Rotate gasket 180o and press firmly into the gasket channel starting...

Страница 16: ...Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with...

Страница 17: ...remove the two screws holding the assembly to the door Reinstall on the opposite end of the door 3 Rotate gasket 180o aligning notch with magnet assembly and pressing firmly into the gasket channel st...

Страница 18: ...or gasket is not pinched on the hinge side of the door To align and adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 s...

Страница 19: ...nding on model Replace nuts if used Prepare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be...

Страница 20: ...mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the u...

Страница 21: ...splay and interior light return to normal operation This unit is Star K certified See www star k org for more details 18 21 CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON OFF Press and release Unit...

Страница 22: ...s Star K certified See www star k org for more details 19 22 CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON OFF Press and release Unit will immediately turn On or OFF Adjust ice thickness See Ice se...

Страница 23: ...set point for Refrigerator Freezer Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain s...

Страница 24: ...Sabbath Mode Press and release Display and interior light return to normal operation Clean Mode See Cleaning section Showroom Mode Hold and for 5 seconds The F C symbol will flash Display will be lit...

Страница 25: ...ed the unit is progressing towards the selected temperature Time to reach set point varies based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the...

Страница 26: ...rate cubes Shake the ice bucket instead During periods of limited use or high ambient temperatures it is common for cubes to fuse together Gently shake the bucket to break apart cubes If not using the...

Страница 27: ...echecking ice thickness Ice is produced in layers resulting in a clear cube Ice in bin may develop surface frost which disappears when cube is placed in liquid Ice cubes in any given batch will vary s...

Страница 28: ...ly melts in the bin the level of ice drops and ice production resumes This ensures a constant supply of fresh ice is always available THINNER BRIDGE THICKER BRIDGE DEEPER DIMPLE SHALLOWER DIMPLE 1 4 T...

Страница 29: ...leanser and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using abrasive pads such as S...

Страница 30: ...to force ice from the evaporator Damage may result 1 Turn the ice machine off and allow any ice to melt off of the evaporator 2 Remove all ice from the storage bin 3 Remove evaporator cover 4 Remove...

Страница 31: ...150 250 4 months 250 400 3 months or sooner Hardness Level mg L ppm Cleaning Interval 0 66 6 months 67 133 4 months 134 200 3 months or sooner USER GUIDE Under normal conditions cleaning should be don...

Страница 32: ...and some water will exit the vent tube Remove cleaning tube Optional for deeper cleaning allow solution to soak for 60 minutes b Press and release 5 04 will appear in the display a The machine will c...

Страница 33: ...ng the hose and funnel slowly pour 1 5 quarts 48 oz of clean potable water into the ice dispenser tube Air and some water will exit the vent tube d Install new water filter Press and rotate 1 4 turn c...

Страница 34: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Отзывы: