background image

QUICK START GUIDE

u-line.com

QUICK START GUIDE

u-line.com

Drain

Model numbers including “CL” or “NB” do not include a 
factory installed drain pump.

Model numbers including “CP” or “NP” include a factory 
installed drain pump.

DRAIN CONNECTION

CAUTION

!

If your U-Line unit did not come with a factory 
installed drain pump you must use a gravity 
style drain connection. For assistance in 
determining if your unit has a pump please 
contact U-Line. The floor drain must be large 
enough to accommodate drainage from all 
attached drains. Follow these guidelines when 
installing drain lines to prevent water from 
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may 
result in personal injury or property damage. 

Drain can NOT be located directly below the unit. 
Unit has a solid base that will not allow the unit 
to drain below itself.

There is a possibility that hose connections may 
have loosened during shipment. 

Verify all connections and fittings are free from 
leaks.

GRAVITY DRAIN

A gravity drain may be used if:

Drain line has at least a 1" drop per 48" (approximately 
2 cm drop per 100 cm) of run.

Drain line does not create traps and is vented per local 
code.

1. Cut the pre-installed drain tube to length.

2. Connect to your local plumbing per the local code.

3. If necessary, insulate drain line to prevent 

condensation.

CAUTION

!

Failure to connect water supply or drain line 
connections properly can result in personal 
injury and property damage. Gravity drain 
connections must be routed downward from the 
rest of the unit at the rate of 1/4" per foot (1 cm 
per 50 cm). 

Normal

Proper Drain

With Trap

Poor Drainage, Water Will Back Up

With Trap and Vent

Proper Drain

8

12

Содержание Outdoor Onb115

Страница 1: ...QUICK START GUIDE Outdoor Collection 30634 Rev_A 30634 Rev_E...

Страница 2: ...consin USA and select products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product...

Страница 3: ...rge when you register your product on u line com See complete warranty for details CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Water Hookup 6 Drain 12 Door Swing 13 Door Ad...

Страница 4: ...safety statement may result in minor or moderate personal injury property or equipment damage Your product may contain R600a Isobutane which is a flammable hydrocarbon To confirm check serial tag insi...

Страница 5: ...repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting...

Страница 6: ...installation Use caution when handling back panel The edges could be sharp CAUTION CAUTION CAUTION USER GUIDE u line com Water Hookup Water Hookup PREPARE PLUMBING The water valve uses a standard 1 4...

Страница 7: ...nlet 4 Break away filler feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn on water supply and ch...

Страница 8: ...installation Use caution when handling back panel The edges could be sharp CAUTION CAUTION CAUTION Water Hookup Clear Ice Machines USER GUIDE u line com Water Hookup Water Hookup PREPARE PLUMBING The...

Страница 9: ...mal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break awa...

Страница 10: ...stallation Use caution when handling back panel The edges could be sharp CAUTION CAUTION CAUTION Water Hookup Nugget Ice Machines USER GUIDE u line com Water Hookup Water Hookup PREPARE PLUMBING The w...

Страница 11: ...pply and disconnect electrical supply to product prior to attempting installation 2 Remove the back panel 3 Thread water line through back panel hole with bushing 4 Locate water valve inlet and connec...

Страница 12: ...an NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify...

Страница 13: ...clearance is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are...

Страница 14: ...t pinched on the hinge side of the door To align and adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on t...

Страница 15: ...bottom hinge Install two or three screws depending on model Replace nuts if used Prepare door for reinstallation 1 Remove gasket 2 Rotate gasket 180o and press firmly into the gasket channel starting...

Страница 16: ...Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with...

Страница 17: ...remove the two screws holding the assembly to the door Reinstall on the opposite end of the door 3 Rotate gasket 180o aligning notch with magnet assembly and pressing firmly into the gasket channel st...

Страница 18: ...or gasket is not pinched on the hinge side of the door To align and adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 s...

Страница 19: ...nding on model Replace nuts if used Prepare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be...

Страница 20: ...mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the u...

Страница 21: ...splay and interior light return to normal operation This unit is Star K certified See www star k org for more details 18 21 CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON OFF Press and release Unit...

Страница 22: ...s Star K certified See www star k org for more details 19 22 CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON OFF Press and release Unit will immediately turn On or OFF Adjust ice thickness See Ice se...

Страница 23: ...set point for Refrigerator Freezer Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain s...

Страница 24: ...Sabbath Mode Press and release Display and interior light return to normal operation Clean Mode See Cleaning section Showroom Mode Hold and for 5 seconds The F C symbol will flash Display will be lit...

Страница 25: ...ed the unit is progressing towards the selected temperature Time to reach set point varies based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the...

Страница 26: ...rate cubes Shake the ice bucket instead During periods of limited use or high ambient temperatures it is common for cubes to fuse together Gently shake the bucket to break apart cubes If not using the...

Страница 27: ...echecking ice thickness Ice is produced in layers resulting in a clear cube Ice in bin may develop surface frost which disappears when cube is placed in liquid Ice cubes in any given batch will vary s...

Страница 28: ...ly melts in the bin the level of ice drops and ice production resumes This ensures a constant supply of fresh ice is always available THINNER BRIDGE THICKER BRIDGE DEEPER DIMPLE SHALLOWER DIMPLE 1 4 T...

Страница 29: ...leanser and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using abrasive pads such as S...

Страница 30: ...to force ice from the evaporator Damage may result 1 Turn the ice machine off and allow any ice to melt off of the evaporator 2 Remove all ice from the storage bin 3 Remove evaporator cover 4 Remove...

Страница 31: ...150 250 4 months 250 400 3 months or sooner Hardness Level mg L ppm Cleaning Interval 0 66 6 months 67 133 4 months 134 200 3 months or sooner USER GUIDE Under normal conditions cleaning should be don...

Страница 32: ...and some water will exit the vent tube Remove cleaning tube Optional for deeper cleaning allow solution to soak for 60 minutes b Press and release 5 04 will appear in the display a The machine will c...

Страница 33: ...ng the hose and funnel slowly pour 1 5 quarts 48 oz of clean potable water into the ice dispenser tube Air and some water will exit the vent tube d Install new water filter Press and rotate 1 4 turn c...

Страница 34: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...