TYROLIT
Hydrostress AG
Page 37
WSE1621 Control unit
Servicing and maintenance
High-presure cleaning
Caution
Cleaning using high-pressure cleaning equipment is not permitted. The WSE1621 Wall saw
could be damaged if it is cleaned with high-pressure cleaning equipment.
Products containing cleaning agent can damage parts of the WSE1621 Wall saw, the remote
controller and the cables.
High-pressure cleaner
4
Maintenance and servicing table
Bef
or
e each use
A
ft
er finishing
wo
rk
W
eek
ly
A
nnually
A
ft
er faults
A
ft
er damage
Electrical system
X
Check the condition and cleanliness of
electric cables, plugs/connectors and
switches.
X
X
X
X
X
Check the condition and cleanliness of
couplings.
X
X
X
X
Water economy
X
Check water lines for cleanliness and leaks.
X
X
X
X
X
Blow out the water if there is a risk of frost.
X
X
X
Overall WSE1621
Control unit
X
Clean with a damp cloth,
do not use a high-pressure cleaner.
X
Service
X
To be performed by TYROLIT Hydrostress
AG or an authorised workshop.
First service after 100 operating hours
Further services after every further 200 operating hours
4.1