WSE1621 Control unit
Electrical data
Technical data
Parameter
Value
Protection class
IP 65
Connected values
400 to 480 VAC / 50 - 60 Hz
Power consumption
16 to 32 A (400 V / 50 Hz)
Output
at 16 A
11 kW
at 32 A
20 kW
Internal control voltages
Computer/remote controller
24 VDC
Feed drives
48 VDC
Main drive unit
400VAC = 565VDC
480VAC = 680 VDC
Converter
High-frequency, water-cooled
Water
Technical data
Parameter
Value
Water
Cooling the control unit
Water cooling the power semi-
conductors
Cooling water flow rate
Min. 4 l/min at max 25 °C
Water connection
2 to 6 bar
Ambient temperature recommendation
Ambient temperature
Parameter
Value
Storage
-20 °C to 50 °C
Operation
-15°C to 45°C
Remote controller
Remote controller
Parameter
Value
Cable length (optional)
10 m
Nominal voltage
24 VDC
Protection class
IP 65
Weight
1.8 kg
Frequency
2.4 GHz