16
TROUBLESHOOTING
Problem
Possible cause
Solution
Machine does not run
when switched on
Power cord not properly
fixed / plugged in
Check that the machine is properly
connected to the power supply.
Power cord defective
Have the power cord checked, replace
if necessary.
Main power switch
defective
Have the main power switch checked
and replace if necessary by a qualified
electrician.
Loose eleectrical
connection inside the
electric system
Have the whole electric system of the
machine checked by a qualified
electrician.
Motor defective
Have the motor checked and replace if
necessary by a qualified techician.
Motor stops
(power cut out)
To much pressure exerted
while cutting
Exert less pressure when cutting
Incorrect specification for
saw blade
Use a saw blade which corresponds to
the material being cut
Saw has a defective electric
system
Have the electric system of the saw
checked by a qualified technician
Poor machine
performance little
power
Power cord/extension cable
too long or cable still wound
up inside cable drum
Use a power cord/ectension cable of
the rated length, use a cable drum with
cable fully extended
Power network is
insufficient
Observe the electrical ratings of the
machine and connect it only to a power
network which complies with these
ratings
Drive motor no longer runs
at rated speed (r.p.m.)
Have the motor checked by a qualified
electrician and have it replaced if
necessary
Содержание TBE350 Series
Страница 1: ...10996400 en 28 09 2016 Operating Instructions TBE350 Table Saw Index Indice 001...
Страница 26: ...26...
Страница 27: ...27...