18
rpm, the end condensation is sewed by the speed of 1200 rpm.when the
work speed is less than 1200 rpm, it is done as work speed.
2)
The condition for end condensation to work is: all of the C,D,U value is
larger than 0 and the indicator for end condensation is on.
3)
The end condensation is the latest sewing operations.
4)
To disable end condensation, press “End condensation” key for four
times. When it is disabled, the indicator for end condensation is off.
2.13 Setting the Position of the Sewing Base line
The default sewing base line is in the center of the zigzag range.The
max.adjustment range is
±
4 mm distance from the center.
■
Operation Steps
1)
Press “Baseline position” key in the normal state, the indicator nearby the
key will be lit up. The main display will show the current base line
position. Such as “L-00”.
2)
Press “Set” key to enable the change of the base line position.
3)
Press “N1+” key to select the rightward change of the base line.The main
display will show “r-**”. Or press “N1-” key to select the leftward
change of the base line. In that case the main display will show “L-**”.
4)
Press the corresponding “+/-” key to change the base line position. The
range of the adjustment range is ( 8.0mm – The work zigzag width) /2.
5)
Press “Set” key to save the changes made. The main display show the
current base line position for a second and then show the work width. If
the current base line position is not 0, the indicator for baseline will be lit
up, otherwise, it is off.
■
Note
To get rid of the baseline setting, please change the value to 0.
2.14 Needle Left/Right Stopping
When the machine is on the normal state, pressing “Left/Right Stop” key can show the
current stop state on the main display. There are 3 kind of left-right stop state.
Left
Stop
the
display
show
“
三 - - -
”
Right
Stop
the
display
show
“
- - -三
”
Free
Stop
the
display
show
“
- - - -
”
End
Stop
the
display
show
“
- -三-
”
To set the left-right stop state, operate as following:
1)
Press “Set” key. The main display show current stop state and blinks.
2)
Press “N1+” key to set to left stop,or press “N4+” key to set to right