Labjack for Focal Height Adjustment:
Minilase™
e features a high precision
labjack system for focal height
adjustment.
Adjusting Focus: Your Minilase
™ system is equipped with an easy focus
finder system comprised of two red aiming beams emitted from the
marking head. One beam is emitted from the center of the lens while the
other is mounted to the side of the lens. This makes focusing simple. The
secondary aiming beam that is emitted from the side of the lens is set to an
angle. This angle is carefully positioned to intercept with the red aiming
beam coming straight from the lens. This distance from the lens shows
where the laser system is in focus.
Simply speaking, when the two red aiming beams are on top of each other,
the laser system is in focus. When they are not on top of each other, the
laser system is out of focus.
See the example images below.
Out of Focus In Focus