background image

5

 

STEP 6:

 Route CAT5/6 cable from the antenna into the building. Al-

ways create a strain relief near the antenna so the cable is not pulling 

directly on the antenna. Use the CAT5/6 strain relief hook feature built 

into the housing back fin. The Ethernet spec allows for a maximum ca-

ble length of 100 meters or about 328 feet.

 

STEP 7:

 Connect a CAT5/6 cable from your com-

puter, switch or router to the LAN port on the 

desktop PoE inserter. Connect the CAT5/6 from 

the antenna to the POE port on the desktop PoE 

inserter. Plug the desktop PoE inserter into a 

surge protected AC power source to power up the 

EZ

-

Go

®

. NOTE: The EZ

-

Go

®

 LT+ will operate 

from 12V to 24V. 

 

CAUTION: 

Applying a voltage higher than 24V will damage the unit and 

void the warranty. Do not plug the antenna directly into a standard  

Active PoE port which may operate at voltages of 48V or higher.

 

Software Settings

 

 

1. There is an HTML management system built into every EZ

-

Go

®

 unit 

which is accessed thru a standard web browser. The unit can communi-

cate thru the CAT5/6 Ethernet cable connection or thru the wireless 

bridge connection, so you can manage remote units from a single loca-

tion.

 

NOTE: 

The device will usually go into a 1

-

2 minute reboot cycle when 

clicking on SAVE & APPLY CHANGES. During this time it will be unre-

sponsive. The unit will beep once when it reboots and beep twice when 

it is ready.

 

2. 

IP  ADDRESS: 

Default IP address for the EZ

-

Go

®

 is 192.168.1.239. 

To access the EZ

-

Go

®

, your computer IP address must be on the same 

subnet ie; 192.168.1.xxx. The EZ

-

Go

®

 ships with DHCP client enabled 

so if the unit has access to your network it will get its IP address auto-

matically from  your network. To find the  units IP address use the  Dis-

covery  Tool. We  recommend  after  everything  is  working  to  your  satis-

faction that you assign a unique static IP to the unit so you always know 

how to access the units on your network. The IP address setting can be 

changed at NETWORK | INTERFACES | EDIT LAN | PROTOCOL

 

3. 

CHANNELS: 

The default channel is set to AUTO.  The EZ

-

Go

®

 client 

unit will automatically find the channel of the connected AP if the SSID 

(ie; 

EZ

-

Bridge

) and Wireless encryption settings are the same on AP 

and Client. Also  on the  AP if Mac  Address  Verification is turned on,  it 

must be disabled or the new client MAC address needs to be in the al-

lowed list.

 

4. 

SECURITY:

  Security  is  pre

-

configured  with  system  passwords  and 

WPA2 encryption  pre

-

set. This is so that you can setup a link to an ex-

Содержание EZ-Go +

Страница 1: ...igh Performance 802 11 Wireless Bridge Router Achieve up to 100 Mbit sec speed Link up to 3 miles with good line of sight Best security available WPA Field Proven Wireless Technology Now with TyconOS Firmware ...

Страница 2: ...r than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install the antenna on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Make sure there are no people pets etc below when you are working on a roof or ladder Watch out for any pow...

Страница 3: ... above the number that says computer 192 168 1 87 is the IP address for the computer that opened the Discovery Tool To access the EZ Go your computer IP address must be on the same subnet ie 192 168 1 xxx In the example above 87 replaces xxx If your computer is not on the same subnet as the EZ Go unit you will either need to change the IP address of your computer or the EZ Go The unit ships from t...

Страница 4: ... using customer supplied screws To mount to a pole Use the supplied U Bolt and wing nuts Make sure to use a lock washer at each wing nut Tighten wing nuts evenly by hand Use pli ers if additional tightness is needed STEP 3 Mount the antenna housing to the bracket Put the hex head bolt thru the housing back fin Put the star lock washer so it is be tween plastic housing and metal bracket Install win...

Страница 5: ... from a single loca tion NOTE The device will usually go into a 1 2 minute reboot cycle when clicking on SAVE APPLY CHANGES During this time it will be unre sponsive The unit will beep once when it reboots and beep twice when it is ready 2 IP ADDRESS Default IP address for the EZ Go is 192 168 1 239 To access the EZ Go your computer IP address must be on the same subnet ie 192 168 1 xxx The EZ Go ...

Страница 6: ...e at close range there is too much power and it has a tendency to overload the input stage of the units and perfor mance degrades The best performance will be seen with signal strength of 40 to 60dBm This signal strength can be viewed on the STATUS OVERVIEW page To change the Tx power go to NET WORK WIFI EDIT TRANSMIT POWER NOTE We recommend if changing power start by cutting it in half check sign...

Страница 7: ...Antenna Beamwidth H V 35 deg 27 deg Antenna Front to Back 20dB 22dB Polarization MIMO MIMO PoE Specification Power Over Ethernet INPUT 100 240VAC 50 60Hz OUTPUT 24VDC 0 5A Average Power Consumption 4W Mechanical Specifications Color White Dimensions L x W x H 12 4 x 7 3 x 2 5 314 x 187x 65mm System Weight 7 lb 3 kg Ethernet Connector RJ45 Mount Pole up to 2 dia or Wall Environmental Specifications...

Страница 8: ...s ready 9 CHANGING OPERATING MODE The EZ Go can be changed to an Access Point device on the NETWORK WIFI EDIT INTERFACE CONFIGURATION MODE page You might change a unit to AP if you wanted to use the unit as an access point talking to multiple clients We recommend using Access Point WDS and Station WDS in most cases to maintain the highest level of network transparency 10 AUTOMATIC REBOOT We highly...

Страница 9: ...ssues can usually be helped by moving the antenna to a new location with better line of site If signal level is good between 35 and 75dBm try chang ing the wireless channel on the AP unit You should also do a site sur vey on both units to see what channels are already being used Select a channel that is not already used or one that has a very low signal strength If the signal level is too hot 30dB...

Страница 10: ...een the PoE Inserter and antenna 6 PAINTING The EZ Go unit can be painted to match a particular house color Only non metallic enamel or latex paints should be used If a paint with metal content is used it will block the microwaves and cause reduced performance 7 COMMON MICROWAVE BARRIERS Tinted windows are made by applying a metallized film to the window If a window has tinting it will usually blo...

Страница 11: ...the AP and the wireless encryption type that is being used B Associated Stations This section shows the stations that are communicating with this Access Point It provides information about the station MAC Address Network or ESSID Signal level being received from the station noise level negotiated TX and RX rates and Transmit CCQ TX CCQ which is a measure of signal quality good is 80 C System Secti...

Страница 12: ...d total free memory If free memory is showing near zero you need to reboot the unit to clear memory E Network Section Shows information about the LAN and WAN interfaces The WAN interface is only active if the unit is configured as a router NOTES ...

Страница 13: ...13 Explanation of LEDs and Connections NOTES ...

Страница 14: ...receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly ap proved by the party responsible for compliance could void the user s authority to operate this...

Страница 15: ...all shipping charges incurred to ship the product to Tycon Systems Ty con Systems pays shipping charges to return the product to the origi nal purchaser For all other countries the original purchaser shall pay all shipping broker fees duties and taxes incurred in shipping products to and from Tycon Systems Provided the goods have not been modi fied or repair attempted by someone other than Tycon S...

Страница 16: ...16 8000004 Rev12 EZ Go LT Qwik Install Guide NOTES ...