PowerSeries Neo Installation Guide
HS2016: 2083333
HS2032: 1388888
HS2064/HS2128: 1052631
HS2064 E: 200000
HS2128 E: 100000
Warning Device Output
l
Integral sounder capable of 85 dB @ 3m, self-powered type Z
l
2 remote, wireless indoor/outdoor warning devices supported: models
PGX901 (indoor), PGX911 (outdoor) (X=4, 8, or 9)
l
Programmable as steady, pulsed or temporal three (as per ISO8201) and tem-
poral four (CO alarm) output
l
Warning device sounds alarms in the following priority: fire, CO, burg
Note:
For NFA2P certified systems the delay for operating the warning device
shall be set to max. 10 min.
Memory
l
CMOS EEPROM memory
l
Retains programming and system status on AC or battery failure for 20 years
min.
Power Supply - International
l
Input ratings: 220V-240Vac, 50/60Hz, 200mA
l
Transformer required, mounted in the same enclosure, permanently
connected
l
Transformer secondary ratings: 16.5Vac, 40VA min.
Note:
For installations using the transformer mounted inside the cabinet, replace
fuse only with the same type (20mm) rated 250V/315mA.
Regulated power supply:
l
1.7A regulated, supervised and integral to the control unit
l
Type A as per EN50131-6 Standard
l
700mA auxiliary supply, 12V DC
l
Positive temperature coefficient (PTC) for Bell, Aux+ and Battery terminals
l
Reverse battery detection/protection
l
Supervision for AC power and low battery
l
Normal and high current battery charge options
l
Supervised battery charging circuit
Current draw (panel):
l
85mA (nominal) 2A(Max)
Bell Output:
l
12V, 700mA supervised (1k Ohm) bell output (current limited at 2 amps)
l
Steady, Pulsed, Temporal 3 fire, Temporal 4 CO alarm cadences
l
Bell short detection (so hardware)
Aux+:
l
Voltage range = 9.6V - 13.8V DC
l
Current = 700mA (shared with Corbus R(ed))
l
Output ripple voltage: 270mVp-p max.
l
Onboard programmable outputs:
l
PGM 1 - 50mA switched programmable output
l
PGM 2 - 300mA current-limited switched programmable output. 2-Wire
smoke detectors (90mA current limited) are supported using this PGM
l
PGM 3 - 50mA switched programmable output
l
PGM 4 - 50mA switched programmable output
l
Hardware PGM over current protection
Battery
l
12V sealed lead acid, rechargeable
l
Battery capacity:
l
12 hours (EN50131),
l
24 hours INCERT [Belgium]
Note:
For T 014 compliance (INCERT certification), only 14Ah (2x7Ah)
batteries were tested and are accepted for INCERT certified systems.
l
Maximum standby time: 24 hours (with 14Ah battery and Aux current limited
to 470mA)
l
Recharging time to 80% 72 hours
l
Recharging rate: 240mA (12 hours max.), 480mA (24 hour backup)
l
Backup time: 24 hours
l
Battery lifespan: 3-5 years
l
Low battery trouble indication threshold 11.5VDC
l
Battery restore voltage 12.5V
l
Main board current draw (battery only):
l
HS2016/32/64/128 (no alternate communicator) standby 85mA DC
l
HS2016/32/64/128, (including alternate communicator) standby 190mA
DC
l
Transmit (alternate communicator module) 195mA DC
l
Resettable fuses (PTC) used on circuit board
l
Supervision for loss of primary power source (AC fail), battery loss or bat-
tery low voltage (battery trouble) with indication provided on the keypad
l
Internal clock locked to AC power frequency
Operating Environmental Conditions
l
Temperature range: EN= -10°C to 55°C (50°F-131°F)
l
Relative humidity: <93% non condensing
Alarm Transmitter Equipment (ATE) Specification
l
Digital dialer integral to the main control board
l
Supports SIA and Contact ID
l
Complies with TS203 021-1, -2, -3 Telecom equipment requirements and
EN50136-1-1, EN50136-2-1, EN50136-2-3 ATS 2
l
Optional Dual IP/Cellular communicators (3G2080(R)E/ TL2803G(R)E/
TL280(R)E) can be installed in the same enclosure and configured as
primary or back-up, with AES 128-bit encryption
l
Compliant with EN50136-1-1, EN50136-2-1 ATS2 requirements
System Supervision Features
The PowerSeries Neo continuously monitors a number of possible trouble
conditions and provides audible and visual indication at the keypad. Trouble
conditions include:
l
AC power failure
l
Zone trouble
l
Fire trouble
l
Telephone line trouble
l
Communicator trouble
l
Low battery condition
l
RF jam
l
AUX power supply fault
l
Failure to communicate
l
Module fault (supervisory or tamper)
Additional Features
l
2-way wireless device support
l
Visual verification ( audio)
l
Proximity tag support
l
PGM scheduling
l
Quick arming
l
User, partition, module, zone and system labels
l
Soak test
l
Programmable system loop response
l
Keypad and panel software versions viewable through keypad
l
Doorbell zone type
l
Low battery PGM type