background image

PowerSeries Neo Installation Guide

Figure 1-6 Telephone Line Wiring

Telephone format is programmed in option [350]. Telephone call directions are
programmed in options [311]- [318].

Ground Wiring

Figure 1-7 Ground Installation

Note:

Using an insulated green wire (minimum 22AWG), connect the EGND

terminal on the Corbus and the grounding wire from the building electrical
installation to any of the available holes on the back or side of the metal cabinet.
See the diagram attached to the cabinet for suggested GND point location and
hardware recommendations.

Note:

Wire and installation hardware not included.

Enrollment

All optional modules and devices must be enrolled on the system. During
enrollment, the electronic serial number (ESN) of each device is identified to the
control panel and zones are assigned. A wireless transceiver HSM2HOST or an
RF keypad must be enrolled first before wireless devices can be enrolled.

Enrolling Modules

During automatic and manual enrollment, if an attempt is made to enroll more
than the maximum number of modules, an error tone sounds and a message is
displayed on LCD keypads.

Table 1-5 Module Capacity

Module

HS2016 HS2032 HS2064/

HS2064 E

HS2128/HS2128 E

HSM2108 8 Zone expander

1

3

7

15

HSM2208 8 Output
expander

2

4

8

16

Wireless Keypad:

HS2LCDRF(P)X

HS2ICNRF(P)X

HS2LCDWF(P)(V)X

8

8

8

16

HS2TCHP Touchscreen
Keypad

8

8

8

16

HSM2300 Power Supply 1A 3

3

3

4

HSM2204 4 High-current
Output

1

1

3

4

HSM2HOSTx Transceiver

1

1

1

1

HSM2955

1

1

1

1

Modules can be enrolled automatically or manually using section [902] of
Installer programming.

To confirm that a module has been successfully enrolled, use Installer
Programming section [903].

Enroll Wireless Devices

Wireless devices are enrolled via the wireless transceiver module and Installer
Programming section [804][000].

Auto Enrollment

To enroll a wireless device using this method, press and hold the Enroll button on
the device for 2-5 seconds until the LED lights then release the button. The alarm
panel automatically recognizes the device and the keypad displays a confirmation
message. The device ID and next available zone number are displayed. Press [*]
to accept or scroll to another available zone number. Batteries must be installed
in the wireless device in order to enroll.

Pre-Enrollment

Pre-enrollment is a two step process. The first step requires entering each device
ID ([804][001]-[716]). Every wireless device has an ID printed on the sticker
attached to the device. The format is XXX-YYYY where:

l

XXX identifies the type or model of the device

l

YYYY is a short encrypted ID used by the system to identify the specific
device

Pre-enrollment can be done at a remote location and using DLS/SA. The second
step is to press the enrollment button on the device, usually done on location.
Installer Programming does not have to be entered at this step. Both steps must be
performed in order to complete the enrollment.

Programming Methods

The alarm system can be programmed using the following methods:

Table 1-6 Programming Methods

Method

Description

Procedure

Template
programming

Use pre-defined templates to quickly
apply basic programming and to set up
DLS downloading.

Press [899] at the “Enter
Section” screen.

See Template
Programming below for
details.

DLS
programming

Download and apply programming
using DLS 5 v1.3 for Neo v1.0 panels
and DLS 5 v1.4+ for Neo v1.0 and up
products.

For local DLS, use a PC-
Link cable and laptop
with DLS-5 software
installed.

For remote DLS, use a
telephone line, cellular
network or the Internet.

Installer
programming

Manually program all alarm system
and device options.

Press [*][8][installer
code] while the system is
disarmed.

Viewing Programming

Programming sections can be viewed from any system keypad. The method for
viewing and selecting programming options using LCD, LED and ICON keypads
depends on the keypad type used. See below for specific instructions on
programming with each keypad type.

Generally, programming options are accessed in the following way:

1.

Enter Installer Programming mode ([*][8]).

2.

Navigate to a specific programming section.

3.

Select an option to view or change its programming.

All programming options are numbered and can be accessed by navigating
through the menu (LCD) or by keying in the program section number. For toggle
options, the name of the option is displayed (LCD) or LEDs 1-8 are illuminated
(LED and ICON).

Use the keypad numbers to toggle options on or off. Sections requiring data input,
such as phone numbers, display the full data in fields up to 32 characters long
(LCD). To input data, use the scroll keys to select a character then press the
keypad button corresponding to the number/letter required. Scroll to the next
character and repeat the procedure as needed. Press the [#] key to save changes
and exit the program section.

Minimum Required Programming

Once basic installation of the alarm panel is complete, the following general
configuration options can be set.

- 5 -

Содержание DSC PowerSeries Neo

Страница 1: ...expander HSM2208 Power supply HSM2300 4 high current output expander HSM2204 Alternate communicator 3G2080E 3G2080RE TL280E TL280RE LE2080 R TL280LE R TL2803GE TL2803GRE TL8803G TL880LT TL880LE PCL 4...

Страница 2: ...e will only remove the mains power and will not disconnect battery power The installer is respons ible to ensure that a readily accessible mains disconnect device is incor porated in the building for...

Страница 3: ...e Corbus Current Calculation Chart For UL ULC and Commercial Listed applications the total standby and alarm current cannot exceed 700mA Table 1 2 Corbus Current Calculation Chart Item Current mA x Qu...

Страница 4: ...2 wire smoke detectors 24 hr burglary input alarm Note Use SEOL resistors on Fire zones only Figure 1 2 LED Output with Current Limiting Resistor and Optional Relay Driver Output Single End of Line SE...

Страница 5: ...e ID 804 001 716 Every wireless device has an ID printed on the sticker attached to the device The format is XXX YYYY where l XXX identifies the type or model of the device l YYYY is a short encrypted...

Страница 6: ...0 551 556 000 Set up partition account codes 310 001 008 Set up partition timers l Entry exit delay settle delay 005 001 008 l Automatic arming disarming schedule 151 158 001 002 l Auto disarming holi...

Страница 7: ...s 2 to enter the Trouble menu l On an LCD keypad scroll to a trouble type then press to view the spe cific trouble The zone name and trouble condition for each trouble are dis played on the screen l O...

Страница 8: ...ate communicator has stopped responding 10 Alt Comm FTC Trouble The alternate communicator has failed to communicate an internal event not generated by the panel Trouble 12 Not Networked Troubles 01 Z...

Страница 9: ...e l Battery capacity l 12 hours EN50131 l 24 hours INCERT Belgium Note For T 014 compliance INCERT certification only 14Ah 2x7Ah batteries were tested and are accepted for INCERT certified systems l M...

Страница 10: ...Times Partition 1 8 Entry Delay 1 030 sec Entry Delay 2 045 sec CP 01 030 sec Exit Delay 120 sec CP 01 060 sec Settle Delay 010 sec CP 01 000 sec 900 Bell Delay Partition Mask Y Y Y Y Y Y Y Y 901 Day...

Страница 11: ...ence Chime During Quick Exit Delay 8 Bell Squawk on Away Arm Disarm Only 018 System Options 6 1 Test Transmission Exception 2 Real Time Bypass Reporting 3 Armed State PGM ON at End of Exit Delay 4 Not...

Страница 12: ...er Lead OUT 03 DLS Lead IN 04 DLS Lead OUT 05 SA Lead IN 06 SA Lead OUT 07 Event Buffer 75 Full 313 Maintenance Events 3 01 Firmware Update Begin 02 Firmware Update Success 03 Firmware Update Fail 314...

Страница 13: ...0 102 Interval 1 End Time 0000 103 Interval 1 Days Assignment 01 Sunday 02 Monday 03 Tuesday 04 Wednesday 05 Thursday 06 Friday 07 Saturday 104 Interval 1 Holiday Assignment 09 Holiday 1 10 Holiday 2...

Страница 14: ...stem Information and Testing 900 System Information 000 Control Panel Version 001 016 Keypad 1 16 Version Info 101 116 8 HSM2108 1 16 Version Info 201 216 HSM2208 Version Information 460 Alternate Com...

Страница 15: ...011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060...

Страница 16: ...110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 Module Record Module Type Slot Serial Number Module Type Slot Serial Number Wireless Device Record Device Type Zone Serial...

Страница 17: ...on within the house Since many fires occur at night special attention should be given to the escape routes from sleeping quarters 3 Escape from a bedroom must be possible without opening the interior...

Страница 18: ...equipment as per EN50131 1 2006 A1 2009 EN50131 3 2009 EN50131 6 2008 A1 2014 Type A EN50136 1 1 1997 EN50136 2 1 EN50136 2 3 ATS2 Standards This device is suitable for use in systems with the followi...

Страница 19: ...hods a push button switch mounted outside the supervised premises Instructions to be provided for the zone type to be programmed for the key arming or b protective switch i e door contact fitted to th...

Страница 20: ...of merchantability or fitness for a particular purpose and of all other obligations or liabilities on the part of Digital Security Controls Digital Security Controls neither assumes responsibility fo...

Страница 21: ...tuation SOFTWARE PRODUCT LICENSE EULA The SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties The SOFTWARE PRO...

Страница 22: ...OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC DSC MAKES NO OTHER WARRANTIES DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CHANGE THIS WARRA...

Страница 23: ...cipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other ri...

Страница 24: ...ing pursuit of criminal prosecution wherever necessary All trademarks not owned by Tyco are the property of their respective owners and are used with permission or allowed under applicable laws Produc...

Отзывы: