PowerSeries Neo Installation Guide
00 – Null Key
02 – Instant Stay Arm
03 – Stay Arm
04 – Away Arm
05 – No Entry Arm
06 – Chime On/Off
07 – System Test
09 – Night Arm
12 – Global Stay Arm
13 – Global Away Arm
14 – Global Disarming
16 – Quick Exit
17 – Arm Interior
21-24 – Command Output 1-4
29 – Bypass Group Recall
31 – Local PGM Activate
32 – Bypass Mode
33 – Bypass recall
34 – User Programming
35 – User Functions
37 – Time/Date Programming
39 – Trouble Display
40 – Alarm Memory
61-68 – Partition Select 1-8
011 – Keypad I/O (000)
012 – Local PGM Output Timer
Pulse Time (00 minutes)
Pulse Time (05 sec.)
021 – Keypad Option 1
1 – [F] Key Enabled
✔
2 – [M] Key Enabled
✔
3 – [P] Key Enabled
✔
4 – Display Code or X's
✔
022 – Keypad Option 2
1 – Local Clock Display
✔
2 – Local Clock Display 24 Hour
3 – Auto Alarm Scroll
✔
5 – Power LED Option
✔
6 – Power LED AC Present
✔
7 – Alarms Displayed if Armed
✔
8 – Auto Scroll Open Zones
✔
023 – Keypad Option 3
1 – Armed LED Power Save*
2 – Keypad Show Arm Mode
✔
*
3 – 5th Terminal is PGM
Output/Zone
4 – Prox Tag Arm/Disarm
7 – Local Display of Temp.
8 – Low Temperature Warning
030 – LCD Message (16 x 2 hex )
031 – Download LCD Message
Duration (000)
041 – Indoor Temperature Zone Entry
(000)
042 – Outdoor Temperature Zone Entry
(000)
101-228 – Door Chime Sound-Zone 1-
128
00 – Disabled
01 – 6 beeps
✔
02 – "Bing-Bong" Sound
03 – "Ding-Dong" Sound
04 – Alarm Tone
05 – Zone Name
899 Template Programming
– 5-Digit Template Code (5-digit
decimal)
– Central Station Telephone
Number (32-digit decimal)
– Central Station Account Code
(4/6-digit decimal)
– Partition Account Code (4-digit
decimal)
– DLS Access Code (6-digit
decimal)
– Partition Entry Delay (000-255
sec.)
– Partition Exit Delay (000-255
sec.)
– Installer Code
System Information and
Testing
900 System Information
000 – Control Panel Version
001- 016 – Keypad 1-16 Version
Info
101-116 – 8-HSM2108 1-16
Version Info
201-216 – HSM2208 Version
Information
460 – Alternate Communicator
461 – HSM2HOST Version Info
481 – HSM2955 Version Info
501 – 504 HSM2300 1-4 Version
Info
521 – 524 HSM2204 1-4 Version
Info
901 Installer Walk Test
Module Programming
902 Add/Remove Modules
000 – Auto-Enroll All Modules
001 – Enroll Modules
002 – Slot Assignment
003 – Edit Module Slot Assignment
101 – Delete Keypads
102 – Delete HSM2108
103 – Delete HSM2208
106 – Delete HSM2HOST
108 – Delete HSM2955
109 – Delete HSM2300
110 – Delete HSM2204
903 Confirm Modules
000 – View All Modules
101 – Keypads
102 – HSM2108
103 – HSM2208
106 – HSM2HOST
108 – Confirm HSM2955
109 – HSM2300
110 – HSM2204
904 Wireless Placement Test
001-128 – Placement Test Zones
1-128
521-528 – Placement Test
Repeaters 1-28
551-566 – Placement Test Sirens
1-16
601-632 – Placement Test
Wireless Keys 1-32
701-716 – Placement Test
Wireless Keypads 1-16
912 Soak Test
000 – Zone Soak Test Duration
Default: 014
001-128 – Zone Soak Test - Zones
1-128
Battery Settings
982 Battery Settings
000– Panel Battery Settings
01– Panel High Charge
Current (SA
✔
)(FRA
✔
)
(UK
✔
)
010 – HSM2204 Battery Settings
01 – HSM2204 1 High Charge
Current (SA
✔
)(FRA
✔
)
(UK
✔
)
02 – HSM2204 2 High Charge
Current (SA
✔
)(FRA
✔
)
(UK
✔
)
03 – HSM2204 3 High Charge
Current (SA
✔
)(FRA
✔
)
(UK
✔
)
04 – HSM2204 4 High Charge
Current (SA
✔
)(FRA
✔
)
(UK
✔
)
020 – HSM2300 Battery Settings
01 – HSM2300 1 Charge
(SA
✔
)(FRA
✔
)(UK
✔
)
02 – HSM2300 2 Charge
(SA
✔
)(FRA
✔
)(UK
✔
)
03 – HSM2300 3 Charge
(SA
✔
)(FRA
✔
)(UK
✔
)
04 – HSM2300 4 Charge
(SA
✔
)(FRA
✔
)(UK
✔
)
Defaults
989 Default Master Code
990 Installer Lockout Enable/Disable
991 Default Keypads
901-916 – Default Keypad 1-16
999 – Default all Keypads
993 Default Alt Comm
996 Default HSM2HOST
998 Default HSM2955
999 Default System
* Wireless keypads only
- 14 -
✔
= Default