409-10016
ELT Machine 1338600-[
Rev H
20 of 34
Tyco Electronics Corporation
To avoid damaging the applicator, ALWAYS return the precision adjustment lever to the 0" position when finished
using the applicator.
1. Adjust the manual precision adjustment lever to “0” by pulling the lever away from the pivot pin. Lock
the lever in place by releasing it.
2. Install the applicator into the machine as described in Paragraph 4.1.
3. Cycle the machine to crimp three sample terminations. Check the crimp height of the samples. If the
crimp heights are not correct, adjust the crimp height according to Step 4.
Figure 14
Adjustment Lever Reading
(+" above 0.00 mm
[.000 in.] setting)
Read Full Step
.051mm
[.002 in.]
+
2
Read Half Step
0.064 mm
[.0025 in.]
Read Full Step
0.051 mm
[.002 in.]
3
-
-
Adjustment Lever Reading
(-" below .00 mm
[.000 in.] setting)
2
ManualPrecision
Adjustment Lever
Read Full Step
0.051 mm
[.002 in.]
+
2
Read Half Step
0.064 mm
[.0025 in.]
2
+
4. Adjust the crimp height by moving the precision adjustment lever:
a. to the right to increase the crimp height; or
b. to the left to decrease the crimp height.
CAUTION
!