II. Connecting the basic modules to
the control panel:
Step
24
You can find four (4)
14-stranded
flat ribbon cables at each basic
module to connect them to the manifold PCBs
(fig. 3.1-32 and 3.1-33)
. The cables are
marked as 0.1 - 0.4, 1.1 - 1.4, 2.1 - 2.4 and
3.1 - 3.4 as well as the appropriate plug
number. Now put the flat ribbon cables on
the manifold PCBs. The PCB for the two (2)
right basic modules can be found at the right
upper basic module, the PCB for the two (2)
left basic modules are located at the left upper
basic module
(fig. 3.1-31)
.
Step
25
:
Then connect the manifold
PCBs to the control panel using the two (2)
26-stranded
flat ribbon cables. The broad
flat ribbon cables are marked as "
A
"
and
"
B
"
as well as the plug number "
X2
".
Connect the
plug of flat ribbon cable "
A
" to the plug "
X2
"
of the manifold PCB at the right upper basic
module
(fig. 3.1-34)
. The flat ribbon cable "
B
"
has to be laid through the prepared
hole of the left upper
module (OL)
to the
rear side. Then it needs to be laid through
the PVC installation channel at the back and
through the hole again of the right upper
module (OR)
to the front in order to be
connected to the control panel. Please be
aware that you need to follow
these instructions only if it has not been
delivered that way. Now connect the flat
ribbon cable "
B
" to the plug "
X2
" of the
manifold PCB at the left upper basic module.
Step
26
:
Now you can connect the plugs
of the flat ribbon cables "
A
" and "
B
" to the
control panel in the right stainless steel frame
cover
(fig. 3.1-35)
.
Please be aware that the flat ribbon cable "
B
"
must be connected to the
left upper
plug of
the control panel and the flat ribbon cable "
A
"
to the
left lower
plug.
For the use of a display, printer or other
output devices it is necessary to connect the
9-stranded ribbon cable with the plug "
C
" to
the controller on the left side down.
The controller consists of one further plug,
where you can connect your peripheral
devices.
PLEASE NOTE: Connectors and cables are numbered and have to be connected in that exact order!
fig. 3.1-33
fig. 3.1-32
fig. 3.1-31
manifold PCB
right
left
flat ribbon
cable
control
panel
fig. 3.1-35