13
Operative Instructions
4.1 Storage
If the packaged machine is temporarily stored, make
sure that it is not subjected to blows and tampering.
However, it must be placed in a closed, dry, dust-free
environment and protected from atmospheric agents.
When restored, a careful preliminary examination of its
integrity by specialised personnel is necessary.
Absolutely avoid overlapping weights or foreign bodies
on the packaging and the machine.
5 Installation
It is advisable that only furniture for professional use
be positioned in the area around the machine, to avoid
ruining them due to possible leakage of condensation
water.
Ö
IMPORTANT NOTE! For a safe installation,
the electrical disconnector / plug of the
device must be positioned free from any
obstacle and in a visible and accessible
position for the operator, so that it's easy to
control it in case of emergency or prolonged
safe disconnection.
b
HAZARD! Do not install and/or use
the glasswasher in environments with
flammable/explosive atmosphere.
a
WARNING! Make sure that the floor is fit to
support the load of the equipment when in
operation.
a
WARNING! Make sure that the machine is
perfectly vertical and stable, using a spirit
level, if necessary.
Unevenness of the machine surface and height can be
adjusted with the two adjustable feet placed under the
machine itself.
b
HAZARD! All electrical and water connections
(loading/unloading) can only be carried out
by specialised and authorised personnel and
by consulting the relative diagrams.
Before machine positioning make sure that:
- All the components needed for installation and proper
use of the machine were installed: main switch, water
supply taps, drain and anything else needed.
- These components should have all the needed
features and should be installed at the locations
shown in the installation scheme.
a
WARNING! The use of unsuitable parts,
and/or the implementation of installation
procedures other than those shown on the
installation diagram, will immediately void
the machine warranty.
- The characteristics of the electricity network must
be compatible with the values required for correct
operation indicated on the machine identification
plate and on the technical data sheet.
- The machine must be connected to an efficient
earthing system (according to electrical safety
standards).
Ö
IMPORTANT NOTE! The manufacturer is not
to be held liable for any damage caused by
improper grounding of the machine or faulty
power supply.
5.1 Under the counter installation
0.2" / 50 mm
0.07
" /
2,5 mm
0.07
" /
2,5 mm
Fig. 7
The under the counter machine can be inserted under
a continuous worktop or under the sink’s drip surface.
The recess niche must have a minimum space as shown
in Fig. 7.
The presence of adequate air intakes must be
guaranteed to allow the ventilation of the area behind
the machine, in order to avoid creating a closed space
without exchange of air with the room environment.