Operation
Note:
Make sure the machine has been calibrated
properly before starting the spreading application.
1.
Start the engine and place the throttle midway
between the “SLOW” and “FAST” positions.
2.
Set the impeller speed to appropriate broadcast
rate setting and turn on the spray system switch.
3.
Move the throttle to the “FAST” position and
drive forward.
4.
Open the granular gate and begin spreading.
g312557
Figure 27
1.
Effective spreading width—variable 3-25 ft (0.9-7.6 m)
g312556
Figure 28
1.
Fence
3.
Side deflector lowered
2.
Flowers
5.
Evaluate the spread pattern. If adjustments are
needed see the
Spreader Calibration/Pattern
Adjustment
section.
6.
When finished spreading, close the granular gate.
7.
Clean the hopper after
each
spreading session.
Important:
Always empty and clean the
spreader immediately after each use. Failure
to do so may cause the chemicals to corrode
the spreader and other components.
Cleaning the Spreader
1.
Drive the machine to a designated cleaning area.
2.
Stop the spreader-sprayer on a level surface, leave
the motion control lever in the neutral position,
and turn off the engine. Engage the parking brake.
33