Operation
The hour meter is connected to a charge circuit
installed in the engine block and it records the
number of hours that the engine has run. If ignition
switch is left on without engine running, hour meter
will not run.
Granular Impeller Speed Control
Located on the left side of the control console (see
Figure 7).
Rotate the knob counterclockwise to start the
impeller and to increase the speed and pattern width.
Rotate the knob clockwise to decrease speed, pattern
width, and to turn the impeller off.
1
2
3
5
6 7
8 9
10
11
12
13
14
15
4
g314019
Figure 7
1.
Granular impeller speed
control
9.
Spray pressure gauge
2.
Spray system switch
10.
Digital display gauge
3.
Spray pressure control
knob
11.
Spread On/Off
4.
Hose reel handle
12.
Spread pattern control
5.
Spray wand trigger and
lock
13.
Spread deflector lock
6.
Left nozzle spray lever
14.
Caster wheel lock foot
pedal
7.
Center nozzle spray
lever
15.
Spray pump foot button
8.
Right nozzle spray lever
Spray System Switch
Located to the left of the ignition switch.
Push on the top of the switch to turn on the spray
system pump as well as the spot spray foot switch
on the left side of the foot pan. Push the bottom
of the switch to turn the sprayer “OFF”. Once the
pump is turned on, the spray pressure control knob
is turned clockwise to increase pressure and/or
counter-clockwise to release pressure (and create
agitation if the pump is on). The pressure can be
read on the spray pressure gauge (decreasing pressure
from gauge will increase agitation in the tank).
Spray Pump Foot Button
Located on the left side of the operator platform.
Press and hold the foot button to turn the sprayer to
“ON”. Release the foot button to turn the sprayer
“OFF”.
Spray Pressure Control Knob
Located on the left side of the machine.
Rotate the knob clockwise to increase pressure and
counterclockwise to decrease pressure.
The pressure will be displayed on the pressure gauge.
Once the nozzles are opened, there will be a slight
decrease in pressure (adjust accordingly).
Spray Pressure Gauge
Located to the right of the spray levers.
Displays the spray pressure when the machine is
spraying.
Digital Display Gauge
Located on the right side of the boom manifold.
Refer to the digital display User’s Manual for the
display information.
Left Nozzle Spray Lever
Located to the right of the spray wand.
Push the lever forward to turn on the left nozzle
spray. Pull the lever rearward to turn it off.
Center Nozzle Spray Lever
Located to the right of the left nozzle spray lever.
17