V02.00 | 2020/08
177
Example: Direct command in UHF applications (scan read/write head version)
Request
Loop counter
0
Command code
0x0060
Read/write head address
0
Length of EPC
0
Start address
0
Length
2
Command timeout
200
Write fragment no.
0
Read fragment no.
0
Write data
0x02 (CMD), 0x00 (application) – see debus protocol
Response
Loop counter
0
Response code
0x0060
Length
12
Error code
0
Tag within the
detection range
0
Data (bytes) available
0
Tag counter
0
Write fragment no.
0
Read fragment no.
0
Read data
0x02, 0x00, 0x01, 0x02, 0x03, 0x04, 0x8B, 0x20, 0x00, 0x01,
0x00, 0x01
The debus protocol enables the read data to be interpreted as follows:
MSG
ERR
SNR0
SNR1
SNR2
SNR3
GTYP
VERS
HW
0x02
0x00
0x01
0x02
0x03
0x04
0x8B
0x20
0x00
0x01
0x00
0x01
n
Serial number: 0x01020304
n
Device type: 0x208B
n
Software version: v1.00
n
Hardware version: v1.00
Содержание TN-UHF AUS-CDS Series
Страница 1: ...Your Global Automation Partner Instructions for Use TN UHF CDS UHF Read Write Head ...
Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...
Страница 25: ...V02 00 2020 08 25 Right click the Ethernet adapter Start the Topology scan Fig 16 Starting the Topology scan ...
Страница 97: ...V02 00 2020 08 97 Transfer the mapping to the POU Fig 94 Transferring the mapping to the POU ...
Страница 117: ...V02 00 2020 08 117 This displays the device in the project tree Fig 114 TN UHF Q300 CDS EU in the project tree ...
Страница 225: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100003065 2020 08 100003065 ...