8.5.8
Command: UHF continuous presence sensing mode
In Continuous presence sensing mode, a user-defined command (write, read, inventory) is sent
to the UHF read/write head and saved in the read/write head. The read/write heads are auto-
matically switched on in Continuous presence sensing mode as soon as a tag is located in the
detection range. The duration of the scan interval and the on time can be adjusted in the set-
tings of the UHF read/write head. The command is continuously executed until the user termin-
ates Continuous presence sensing mode by executing a reset command.
NOTE
The reset command resets all read data.
Read/write heads in Continuous presence sensing mode send all command related data to the
interface. The data is stored in the buffer of the interface and can be queried by the controller
via the
Get data from buffer
command. In Continuous presence sensing mode the
Tag in
detection range
signal is not permanently updated.
Request
Loop counter
See description of the output data, [
Command code
0x0020 (hex.), 32 (dec.)
Read/write head address
See description of the output data, [
Length of EPC
Not required
Start address
0: Grouping inactive
1: Grouping active
>1: Not defined
Length
Not required
Command timeout
Not required
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0020 (hex.), 32 (dec.)
Length
Not required
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
Increases during command execution
Tag counter
Increases with each read or written EPC
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data
Содержание TN-UHF AUS-CDS Series
Страница 1: ...Your Global Automation Partner Instructions for Use TN UHF CDS UHF Read Write Head ...
Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...
Страница 25: ...V02 00 2020 08 25 Right click the Ethernet adapter Start the Topology scan Fig 16 Starting the Topology scan ...
Страница 97: ...V02 00 2020 08 97 Transfer the mapping to the POU Fig 94 Transferring the mapping to the POU ...
Страница 117: ...V02 00 2020 08 117 This displays the device in the project tree Fig 114 TN UHF Q300 CDS EU in the project tree ...
Страница 225: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100003065 2020 08 100003065 ...