V05.00 | 2022/04
23
8
Operation
8.1
LED indication
Color
Meaning
Off
No power supply present
Green
Positioning element signal detected within taught range
Yellow
Positioning element signal detected outside taught range
Red
No positioning element signal detected
Proceed as follows if no magnetic signal is detected (red LED lit):
Place the positioning element in the active measuring range of the device.
Carry out a voltage reset.
a
The device is automatically adjusted to the signal strength of the positioning element.
8.2
Diagnostics
The LTX with an analog output (4…20 mA) has a diagnostic feedback function. The 4…20 mA
range makes it possible to locate the position of the positioning element in the set measuring
range. If the positioning element is outside of the set measuring range, the analog output
supplies the following values:
n
3.8 mA: Positioning element is located in the blind zone or no positioning element detected
n
3.9 mA or 20.1 mA: Positioning element is located outside of the set measuring range