background image

Turck subsidiaries - contact information

28

Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

15

Turck subsidiaries – contact information

Germany

Hans Turck GmbH & Co. KG
Witzlebenstraße 7, 45472 Mülheim an der Ruhr

www.turck.de

Australia

Turck Australia Pty Ltd
Building 4, 19-25 Duerdin Street, Notting Hill, 3168 Victoria

www.turck.com.au

Belgium

TURCK MULTIPROX
Lion d'Orweg 12, B-9300 Aalst

www.multiprox.be

Brazil

Turck do Brasil Automação Ltda.
Rua Anjo Custódio Nr. 42, Jardim Anália Franco, CEP 03358-040 São Paulo

www.turck.com.br

China

Turck (Tianjin) Sensor Co. Ltd.
18,4th Xinghuazhi Road, Xiqing Economic Development Area, 300381
Tianjin

www.turck.com.cn

France

TURCK BANNER S.A.S.
11 rue de Courtalin Bat C, Magny Le Hongre, F-77703 MARNE LA VALLEE 
Cedex 4

www.turckbanner.fr

Great Britain

TURCK BANNER LIMITED
Blenheim House, Hurricane Way, GB-SS11 8YT Wickford, Essex

www.turckbanner.co.uk

India

TURCK India Automation Pvt. Ltd.
401-403 Aurum Avenue, Survey. No 109 /4, Near Cummins Complex, 
Baner-Balewadi Link Rd., 411045 Pune - Maharashtra

www.turck.co.in

Italy

TURCK BANNER S.R.L.
Via San Domenico 5, IT-20008 Bareggio (MI)

www.turckbanner.it

Japan

TURCK Japan Corporation
Syuuhou Bldg. 6F, 2-13-12, Kanda-Sudacho, Chiyoda-ku, 101-0041 Tokyo

www.turck.jp

Canada

Turck Canada Inc.
140 Duffield Drive, CDN-Markham, Ontario L6G 1B5

www.turck.ca

Korea

Turck Korea Co, Ltd.
B-509 Gwangmyeong Technopark, 60 Haan-ro, Gwangmyeong-si, 
14322 Gyeonggi-Do

www.turck.kr

Malaysia

Turck Banner Malaysia Sdn Bhd
Unit A-23A-08, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 
46200 Petaling Jaya Selangor

www.turckbanner.my

Содержание LTX-EF10 Series

Страница 1: ...Your Global Automation Partner Instructions for Use LTX Linear Position Sensors with Analog Output ...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Страница 3: ...ignal control 9 4 4 2 Current output 9 4 4 3 Voltage output 9 4 4 4 Preferred types LTX M F10 LI0 X3 H1151 measuring range 10 4 5 Technical accessories 11 5 Installing 15 5 1 Mounting the device in a hydraulic cylinder 16 5 1 1 Mounting the sensor 17 5 2 Fastening the device with mounting bracket externally 18 5 2 1 Mounting additional mounting brackets for external mounting 19 5 2 2 Installing th...

Страница 4: ... Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com 11 Maintenance 26 12 Repair 26 12 1 Returning devices 26 13 Disposal 26 14 Technical data 27 14 1 Update time 27 15 Turck subsidiaries contact information 28 ...

Страница 5: ...es a dangerous situation with medium risk of death or severe injury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situation which may lead to property damage if not avoided NOTE NOTE indicates tips recommendations and useful information on specific actions and facts The notes simpl...

Страница 6: ... Connector type H1 Male connector M12 1 Preference type LTX 100 M F10 LI0 X3 H1 1 5 1 LI0 X3 Electrical version Number of LEDs X3 3 color LED Output type LI0 4 20 mA LI1 20 4 mA LU0 0 10 V LU1 10 0 V LU2 10 10 V LU3 10 10 V LU4 0 5 V LU5 5 0 V LU6 5 5 V LU7 5 5 V NOTE Types with manufacturer compatible connectors and models with customized blind zones are available on request The preferred types a...

Страница 7: ... option the devices can also be used for level measurement The measuring range is adjustable The devices may only be used as described in these instructions Any other use is not in accord ance with the intended use Turck accepts no liability for any resulting damage 3 2 General safety instructions n The device meets the EMC requirements for industrial areas When used in residential areas take meas...

Страница 8: ...ed homing or recalibration All position values are determined as absolute values Homing movements after a voltage drop are unnecessary 4 1 Device overview 24 44 5 ø 44 5 ø 10 3 10 M18 x 1 5 x 25 M12 x 1 81 3 L 63 5 Blind zone 50 8 Blind zone Measuring range Fig 1 LTX device dimensions with standard blind zones in mm 4 1 1 Indication elements Each device has a 3 color LED for indicating the operati...

Страница 9: ...lement see output characterist ics A 4 B A B I mA 20 Fig 2 Output characteristics devices with 4 20 mA current output A U V 0 B A B 10 Fig 3 Output characteristics devices with 0 10 V voltage output 4 4 1 Automatic signal control The device is automatically adjusted to the signal strength of the positioning element as soon as the sensor is supplied with power The automatic signal control fully com...

Страница 10: ...re turck com www turck com 4 4 4 Preferred types LTX M F10 LI0 X3 H1151 measuring range Preferred types LTX M F10 LI0 X3 H1151 are available with the following measuring lengths as standard Measuring range Configured 100 500 mm in 25 mm increments 500 2000 mm in 50 mm increments 2000 7600 mm in 500 mm increments ...

Страница 11: ...9 STM AL R10 6900409 Standard 4 hole positioning element aluminum suitable for mounting in the hydraulic cylinder ø 25 4 7 9 ø 13 5 CM R10 6900416 Standard positioning element suitable for mounting in the hydraulic cylinder S N ø 63 5 ø 4 75 ø 19 05 9 65 S S 35 74 10 31 LSPM AL R10 6900414 Ring positioning element with slot aluminum can be used for external mounting with RB R10 mounting bracket ...

Страница 12: ...10 6900417 Float positioning element stainless steel specific gravity 0 62 kg m for external mounting for level monitoring Spacer Dimension drawing Type ID Description ø 32 8 ø 23 8 ø 4 7 ø 13 5 16 8 6 4 STS R10 6900411 Standard spacer made from non ferrous material for separating the positioning element from the ferrous base of the hydraulic piston rod suitable for mounting in the hydraulic cylin...

Страница 13: ...s and standard STS R10 spacer 50 8 19 3 12 7 ø 12 2 ø 10 5 50 8 26 2 ø 7 1 ø 7 1 31 7 50 8 76 2 25 4 15 7 50 8 ø 19 5 MB R10 6900419 Mounting bracket sensor head and rod for external mounting with screws 50 8 19 3 12 7 ø 12 2 ø 10 5 50 8 26 2 ø 7 1 RB R10 6900420 Mounting bracket for rod for external mounting with screws Teach adapter Dimension drawing Type ID Description RP Q21 6900005 Teach adap...

Страница 14: ...er setting common ground asymmetrical Connection cables Dimension drawing Type ID Description 45 4 ø 15 M12 x 1 14 L 50 5 RKS4 5T 2 TXL 6626373 Connection cable M12 female connector straight 5 pin cable length 2 m jacket material PUR black cULus approval other cable lengths and types available see www turck com 45 4 ø 15 M12 x 1 14 L 50 5 RKS4T 2 TXL 6626293 Connection cable M12 female straight 3 ...

Страница 15: ...r the pressure pipe along the entire measuring length deviation 0 5 mm 81 3 3 20 2 5 10 7 1 28 ø 25 4 1 00 ø 44 5 1 75 7 9 31 ø 10 3 405 32 8 1 28 M12 x 1 3 color LED LTX M M18x1 5 6gx25mm thread w jam nut LTX E 3 4 16x1 00 thread w jam nut Viton O ring for 1 2 dia tube boss seal Span 63 5 2 50 Dead band 50 8 2 00 Null Standard 4 hole positioning element STM AL R10 Fig 4 Side view LTX R10 with dim...

Страница 16: ... the hydraulic cylinder Observe the instructions of the cylinder manufacturer and the hydraulic cylinder specifications The devices can be mounted directly in a hydraulic cylinder For this a hole with a recommen ded diameter of 13 5 mm must be provided in the cylinder piston rod depending on the cylinder design To fasten the device an M18 1 5 threaded hole according to ISO 6149 1 is required in th...

Страница 17: ...made of polymer see figure below item 2 The protecting ring prevents mechanical wear of positioning elements by the pressure pipe when the piston is fully extended Fasten the positioning element and spacer with non ferrous screws Remove the protective cap on the hydraulic cylinder if present The bore hole in the cylinder piston rod should have a diameter of at least 13 5 mm Insert the sensor press...

Страница 18: ...tic material NOTE Non ferrous materials such as brass copper aluminum demagnetized stainless steel or plastic do not impair the function of the sensor Loosen the hexagon nut on the thread of the sensor head Guide the mounting bracket over the pressure pipe up to the sensor head If the mounting bracket has an M18 1 5 threaded hole screw tight the sensor directly Fasten the mounting bracket Re faste...

Страница 19: ...material When using additional mounting elements use a ring type positioning element with slot as the positioning element Fit mounting elements made from ferromagnetic already magnetized material at least 7 mm away from both the blind zone and the active measuring range of the sensor Sensors with probe lengths of 750 1800 mm Fit additional mounting elements as shown in fig Mounting positioning ele...

Страница 20: ... entire measuring range When using ring positioning elements with a slot Observe 5 mm distance between the positioning element and measuring probe nominal distance 1 5 mm Push the positioning element into the active measuring range of the sensor Fasten the positioning element with non ferrous screws 50 8 31 8 25 4 11 7 1 25 4 26 2 16 9 36 25 4 15 7 ø 7 1 2x 31 8 50 8 50 8 50 8 ø 7 1 2x 1 2 3 4 6 D...

Страница 21: ...ferential symmetrical input connect the sensor to the higher level as shown in the figure If the higher level input is a common ground asymmetrical input connect the sensor to the higher level as shown in the figure NOTE Keep pin 2 potential free during operation to prevent any accidental teach in operations 6 1 Wiring diagrams NOTE The following figure shows the usual wire colors The assignment m...

Страница 22: ...ystem the system may move in an uncontrolled manner the first time the power supply is connected The device is operational automatically once the cables are connected and the power supply is switched on The positioning element must be located in the active measuring range of the sensor when the power supply is applied in order to ensure the correct tuning of the signal strength control ...

Страница 23: ...y out a voltage reset a The device is automatically adjusted to the signal strength of the positioning element 8 2 Diagnostics The LTX with an analog output 4 20 mA has a diagnostic feedback function The 4 20 mA range makes it possible to locate the position of the positioning element in the set measuring range If the positioning element is outside of the set measuring range the analog output supp...

Страница 24: ...lement at end point of the measuring range Bridge pin 2 and pin 3 for 4 s Sensor starts teach mode Interrupt bridge between pin 2 and pin 3 for 1 s Bridge pin 1 and pin 2 within 5 s a The end point of the measuring range is stored 9 2 Setting via teach adapter RP Q21 Connect the sensor to the teach adapter Place positioning element at the zero point of the measuring range Press the Zero button of ...

Страница 25: ...Risk of injury through uncontrolled ejection of sensor head Ensure in pressurized systems that the pressure pipe is not damaged and pressure proof NOTE The system does not have to be depressurized in a fluid cylinder application Sensor head and measuring element can be replaced independently of the pressure pipe Loosen the screws on the sensor head Pull the sensor and measuring element out of the ...

Страница 26: ...ned if it is faulty Observe our return acceptance conditions when returning the device to Turck 12 1 Returning devices Returns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed The decontamination declaration can be downloaded from https www turck de en retoure service 6079 php and must be completely filled in and affixed securely and weather...

Страница 27: ...ing voltage 7 30 VDC Current consumption 100 mA 15 VDC Short circuit protection Yes cyclic Output function 5 wire analog Design Design Cylindrical smooth Housing material Metal aluminum black Metal stainless steel 304 Active face material Metal stainless steel 316 Vibration resistance 30 Hz 1 mm Shock resistance 100 g 11 ms Pressure resistance temporary 680 bar Pressure resistance permanent 340 ba...

Страница 28: ... S A S 11 rue de Courtalin Bat C Magny Le Hongre F 77703 MARNE LA VALLEE Cedex 4 www turckbanner fr Great Britain TURCK BANNER LIMITED Blenheim House Hurricane Way GB SS11 8YT Wickford Essex www turckbanner co uk India TURCK India Automation Pvt Ltd 401 403 Aurum Avenue Survey No 109 4 Near Cummins Complex Baner Balewadi Link Rd 411045 Pune Maharashtra www turck co in Italy TURCK BANNER S R L Via ...

Страница 29: ...turck ru Sweden Turck Sweden Office Fabriksstråket 9 433 76 Jonsered www turck se Singapore TURCK BANNER Singapore Pte Ltd 25 International Business Park 04 75 77 West Wing German Centre 609916 Singapore www turckbanner sg South Africa Turck Banner Pty Ltd Boeing Road East Bedfordview ZA 2007 Johannesburg www turckbanner co za Czech Republic TURCK s r o Na Brne 2065 CZ 500 06 Hradec Králové www tu...

Страница 30: ...Over 30 subsidiaries and over 60 representations worldwide www turck com D102240 2022 04 D102240 ...

Отзывы: