Installing
Fastening the device with mounting bracket externally
20
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
5.2.2
Installing the positioning element (for external mounting)
Observe a distance of 7 mm between the positioning element and ferrous material. If
necessary, use a spacer.
Observe a distance of 7 mm between the end of the measuring probe and ferrous
material.
The positioning element must not touch the sensor along the entire measuring range.
When using ring positioning elements with a slot: Observe ≤ 5 mm distance between the
positioning element and measuring probe (nominal distance: 1.5 mm).
Push the positioning element into the active measuring range of the sensor.
Fasten the positioning element with non-ferrous screws.
50.8
31.8
25.4
11
7.1
25.4
26.2
16.9
36
25.4
15.7
ø 7.1 (2x)
31.8
50.8
50.8
50.8
ø 7.1 (2x)
1
2
3
4
6
Dead band
Stroke
Null
Fig. 9: Mounting positioning elements
Position
Meaning
1
Sensor
2
Mounting element for sensor head
3
4-hole positioning element (aluminum)
4
Spacer for positioning element
5
Mounting element for positioning element
6
Mounting element for measuring probe