5.1.1
Mounting the sensor
Loosen the hexagon nut on the sensor and remove from the thread.
Ensure that the pressure seal O-ring is located on the sensor head.
Mount the non-ferrous spacer between the positioning element and base of the piston
rod.
Mount the positioning element. Observe a minimum distance of 51 mm between the
positioning element and sensor head with the piston rod in the retracted position. If the
minimum distance cannot be observed, sink the positioning element in the cylinder
piston.
Recommendation for sensors with probe lengths of ≥ 1500 mm: Use a protective ring,
e.g. made of polymer (see figure below, item 2). The protecting ring prevents mechanical
wear of positioning elements by the pressure pipe when the piston is fully extended.
Fasten the positioning element and spacer with non-ferrous screws.
Remove the protective cap on the hydraulic cylinder (if present). The bore hole in the
cylinder piston rod should have a diameter of at least 13.5 mm.
Insert the sensor pressure pipe into the cylinder piston.
Screw the sensor into the M18 × 1.5 threaded bore of the hydraulic cylinder using the
thread of the sensor head (max. tightening torque: 50 Nm).
2
3
4
5
1
Fig. 7: Mounting the device in a hydraulic cylinder
Position
Description
1
Viton O-ring
2
Protective ring (optional)
3
4-hole positioning element
4
Spacer for positioning element
5
13.5 mm bore hole in the cylinder piston rod