V01.00 | 2022/02
17
7
Commissioning
After connecting and switching on the power supply, the device is automatically ready for
operation.
7.1
Commissioning aid — spirit level
The LEDs act as a spirit level when the inclinometer is aligned. The two yellow LEDs are lit when
the position of the inclinometer is within a window of ±0.5° around the center. The LEDs flash
at an increasing frequency the closer the sensor approaches the center position.
One LED flashes with 1-axis movements. Both LEDs flash with 2-axis movements.
The spirit level function can be deactivated via IO-Link. The function is active by default.